English
6
State of charge indicator (Fig. D)
This appliance include a state of charge indicator
3
which
consists of three LED lights that indicate the level of charge
remaining in the battery. This feature is only activated
when the vacuum is powered on and when the vacuum is
on charge.
The state of charge indicator is an indication of approximate
levels of charge remaining in the battery pack.
The LED battery indicator displays the remaining charge and
warns you when the battery is low. The final LED will flash
continuously when there is only very little runtime remaining.
nOTE:
The state of charge indicator is only an indication of
the charge left on the battery.
It does not indicate tool functionality and is subject to
variation based on product components, temperature and
end‑user application.
Use (Fig. E)
This vacuum cleaner can be used in one of two ways.
• With the extension tube
8
and the floor head
9
.
• With the crevice tool
11
.
Switching ON and OFF (Fig. F)
• To switch ON, push the ON/OFF button
1
.
• For increased power, push the ON/OFF button
1
again.
nOTE:
The state of charge indicator LEDs will illuminate
while the vacuum is ON.
• To switch OFF, press the ON/OFF button
1
a third time.
• Return the product to the charger immediately after use
so that it will be ready and fully charged for the next
use. Ensure that the product is fully engaged with the
charger plug.
Floor Sense
Floor Sense is active in the low speed. When a carpet is
detected, the performance of the unit is automatically
increased to high speed. When a hard floor is detected, the
performance of the unit reduces to low speed.
Using an Accessory Tool (Fig. E)
The crevice tool
11
allows for vacuuming in narrow and
hard to‑reach places.
• To attach the crevice tool
11
press into vacuum inlet
14
so it locks into position as shown in Fig. E.
• To release the crevice tool
11
press the crevice tool
release button
15
and gently pull the extension tube off.
MAINTENANCE
WARNING:
To reduce the risk of
serious personal injury, turn unit off before
making any adjustments or removing/installing
attachments or accessories.
An accidental start‑up
can cause injury.
Cleaning
WARNING:
Blow dirt and dust out
of all air vents with clean, dry air at least once a
week. To minimize the risk of eye injury, always
wear ANSI Z87.1 approved eye protection when
performing this procedure.
WARNING:
Never use solvents or other
harsh chemicals for cleaning the non‑metallic parts
of the tool. These chemicals may weaken the plastic
materials used in these parts. Use a cloth dampened
only with water and mild soap. Never let any liquid get
inside the tool; never immerse any part of the tool into
a liquid.
Cleaning and Emptying the Vacuum
WARNING:
Projectile/Respiratory Hazard:
Never use the vac without its filter.
nOTE:
The filter is re‑usable, do not confuse it with a
disposable dust bag, and do not throw it away when the
product is emptied. We recommend that you replace the
filter every 6–9 months depending on frequency of use.
To Empty the Dust Bowl (Fig. I–L)
• Push down the dust bowl release button
4
to release
and remove the dust bowl
5
from the vacuum.
• Use your index finger and thumb to pinch the filter
housing tabs and pull the filter housing
6
from the dust
bowl as shown in Fig. J.
• Place the dust bowl over a trash can and empty the dust
bowl as illustrated in Fig. K.
• Remove the foam filter
17
from the filter housing as
shown in Fig. L.
• Shake or lightly brush any loose dust off of the foam
filter
17
and filter
6
.
• Rinse out the dust bowl
5
with warm soapy water.
• Wash the filters with warm soapy water.
• Ensure the filters are completely dry before refitting the
filters into the filter housing.
• Refit the clean and dry foam filter
17
into the filter
housing
6
.
• Install the filter housing into the dust bowl
5
.
• Install the dust bowl onto the vacuum, until it “clicks”
firmly into position.
Removing and Cleaning the Beater Bar
(Fig. K, L)
WARNING:
To reduce the risk of injury from
moving parts, disconnect the floor head and extension
tube from the vacuum before cleaning or servicing.
• To remove the beater bar
18
from the floor head
9
Slide
the beater bar release button
10
to the rear of the unit.
• The beater bar
18
can now be removed and cleaned.