7.23 Warning Flags
Index
Flag
Description
0
OUTPUT_PWR_LOW_WARNING
Optical output power is lower than the warning limit
1
LASER_HIGH_WARNING
The laser current of one laser is higher than the warning limit (> 130%)
2
TEC_HIGH_WARNING
The peltier current of one laser is higher than the warning limit (< 90%)
3
RF_INPUT_LOW_WARNING
RF signal is lower than the warning limit
4
POWER_SUPPLY_WARNING
One of two power supplies fails (obsolete)
5
FAN_LEFT_WARNING
The left fan (looking from device’s front side) fails (doesn’t rotate)
6
FAN_RIGHT_WARNING
The right fan (looking from device’s front side) fails (doesn’t rotate)
7
OUTPUT_PWR_HIGH_WARNING
Optical output power is higher than the warning limit
8
RF_INPUT_HIGH_WARNING
RF signal is higher than the warning limit
...
12
POWER_SUPPLY_LEFT_WARNING
The left power supplies (looking from device’s front side) fails
13
POWER_SUPPLY_RIGHT_WARNING
The right power supplies (looking from device’s front side) fails
14
OMI_OR_RFGAIN_LOW_WARNING
The calculated rf gain (if AGC on) or the calculated omi (if AGC off) is
lower than the warning limit
15
OMI_OR_RFGAIN_HIGH_WARNING
The calculated rf gain (AGC on) or the calculated omi (AGC off) is higher
than the warning limit
16
+3.3V_LOW_WARNING
3.3V is lower than the warning limit
17
+3.3V_HIGH_WARNING
3.3V is higher than the warning limit
18
+5V_LOW_WARNING
5V is lower than the warning limit
19
+5V_HIGH_WARNING
5V is higher than the warning limit
20
-5V_LOW_WARNING
Supply -5V is lower than the warning limit
21
-5V_HIGH_WARNING
Supply -5V is higher than the warning limit
22
+12V_LOW_WARNING
12V is lower than the warning limit
23
+12V_HIGH_WARNING
12V is higher than the warning limit
24
-12V_LOW_WARNING
Supply -12V is lower than the warning limit
25
-12V_HIGH_WARNING
Supply -12V is higher than the warning limit
26
+24V_LOW_WARNING
24V is lower than the warning limit
27
+24V_HIGH_WARNING
24V is higher than the warning limit
28
LASER_TEMP_DIFF_LOW_WARNING
Laser temperature difference from nominal value is lower than the warning
limit (
≥
1°C below nominal value)
29
LASER_TEMP_DIFF_HIGH_WARNING
Laser temperature difference from nominal value is higher than the
warning limit (
≥
1°C above nominal value)
30
MODULE_TEMP_LOW_WARNING
Module temperature is lower than the warning limit (< 5°C)
31
MODULE_TEMP_HIGH_WARNING
Module temperature is higher than the warning limit (> 65°C)
Table 7.21: Situations triggering a warning flag in the ES10/ES26; Flags in bold letters can be