5.1.3.2 Cleaning the connector of the transmitter device
NOTICE
Cleaning the device connector(s) requires device opening.
Since device opening may damage its function, warranty
extinguishes when doing so!
Therefore, cleaning the connector may be only performed by BKtel
manufacturing engineers or BKtel repair engineers! Please send
device to BKtel in case you assume dirty device’s bushings and/or
connectors!
NOTICE
Only clean device’s bushing and bushing case when no connector is
connected. Extremely dirty bushings must be replaced.
3
3
1. Disconnect the optical connector or remove the
dust cap from the bushing.
2. Dissolve both screws of each optical
connector. Caution: Extract the connector very
carefully!
3. Disconnect the internal optical connector
(inside the device) and clean it as described in
the proceeding section. Caution: Do not extend
the connector by more than 1 cm from the
device body.
4. If the bushing is dirt, disconnect the bushing
fixing by loosing the appropriate screws.
4a. Push the nylon brush through the bushing
casing several times and then blow clean with
rubber
bellows
or
compressed
air.
Rub the outer casing and fiber bushing with a
cleaning cloth, if necessary.
4b. Install bushing in the device again and close