of 86
55
TROUBLESHOOTING
Error Messages on User-Interface
Error Code
Possible Cause
Solution
Brew Chamber Glass
Brew Chamber not installed correctly
1. Remove and reinstall Brew chamber.
Chamber Not Sealed
Purge valve may be stuck open or
clogged with debris.
1. Poke purge valve with purge valve tool to make
sure ball moves and is free of debris. Try a
different purge valve or brew handle.
2. Make sure brew handle and basket are in place
and free of debris.
Brew Chamber not sealed.
3. Make sure locking handle is down and locked in
place.
Brew Handle
Brew Handle not detected
1. Make sure brew handle and basket are in place
when brewing.
Temp. Sensor
Temperature check failed
1. Restart unit and try again.
Flow Meter
No water fl ow detected
1. Check supply water
2. Make sure drain from tower and drain from
WVCS are not connected to each other. Both
should be connect to store drain.
Air in water lines
3. Cycle power and allow the unit to reboot, purging
air from lines. Repeat up to 4 times.