Ventless Hood System
Maintenance
18
Maintenance
Electrocution could occur if this unit is hosed down with water. This unit is NOT
designed for hose wash-down cleaning! Refer to scheduled maintenance below
for proper hood cleaning.
Electrocution could occur if power is not removed from this unit before servicing.
Remove power at disconnect or circuit breaker
BEFORE
servicing hood.
Scheduled Maintenance
Use the following table to help manage scheduled maintenance activities.
FREQUENCY PERFORMED BY
PART
ACTIVITY
Daily
User
Entire Hood
Wipe unit down with a soft rag and mild
cleaning agent.
User
Condensation
trough
Check condensation trough. Empty if
necessary.
User
Grease Baffle
Clean grease baffle. If necessary, refer
to the procedure in this manual for
cleaning the baffle.
Weekly
User
Particle/Odor Filter
Inspect particle/odor filter. In low to
medium volume applications, the filter
may need replacement prior to the
indicating light turning on. This
condition will be evident by a strong
odor coming from the face of the filter.
If necessary, refer to the procedure in
this manual for replacing the filter.
Monthly
User
Door and Filter
Interlock
Check door and filter interlock
operation. The unit should not operate
with the front door open or either the
grease baffle or particle/odor filter
removed. Clean area between grease
baffle and particle/odor filter.
Injury from rotating fan blades could occur if power is not removed from this unit
before cleaning the blower section. Remove power at disconnect or circuit breaker
BEFORE
cleaning the blower section.
3 Months
User
Blower Section
Clean the blower section.
6 Months
Authorized Service
agent
Fire Extinguishing
System
Have the fire extinguishing system
inspected.
Summary of Contents for FH-28CT COUNTERTOP
Page 1: ...CS TM 041 01 Revised 04 17 13 Ventless Hood System MODEL FH 28CT COUNTERTOP Service Manual ...
Page 11: ...Ventless Hood System Installation 9 Figure 1 ...
Page 12: ...Ventless Hood System Installation 10 Figure 2 ...
Page 13: ...Ventless Hood System Installation 11 Figure 3 Right Side Pull Station Mounting ...
Page 14: ...Ventless Hood System Installation 12 Figure 4 Left Side Pull Station Mounting ...
Page 15: ...Ventless Hood System Installation 13 Figure 5 Complete Pull Station Mounting ...
Page 24: ...Ventless Hood System Replacement Parts 22 Figure 7 Blower Motor Assembly ...
Page 26: ...Ventless Hood System Replacement Parts 24 Figure 8 Right Side Cabinet Assembly ...
Page 28: ...Ventless Hood System Wiring Diagrams 26 Wiring Diagrams ...