43
EXTERN
ENABLE
(menu config.)
EXTERN
SHUT-OFF
(menu config.)
Shut-Off
(pin 15)
Output
Display
NOT ACTIVE
(by Default)
OFF / LOW
NOT
ACTIVE
On
No
Display
ON / LOW
NOT
ACTIVE
On
No
Display
ACTIVE
OFF / LOW
High-to-Low
Off
SO
ON / LOW
Low-to-High
Off
SO
CV/CC
Pin 13 can be used to monitor the power supply output mode. The pin will
output a High level (5V) under CV mode, and Low level (0V) under CC
mode.
CV/CC
level
Output Mode
Display
High
Constant Voltage
CV
Low
Constant Current
CC
Local/Analog
Pin 8 can be used to select the control mode (Local or Analog) of the power
supply’s output. When the input command for this pin is at High level (or
open), the control mode will be Local. When input command for this pin is
at Low level (or connected to common GND), the control mode will be
Analog. In analog mode, setting and measurement resolution for voltage
and current will be less than local mode. See the below figures as an
example.