17
8) Remove the inspection screw for the oil chamber (pos#50-08). Pour
out a small sample of the oil. If it is milky white, or contains water, then
the oil and possible, the mechanical seal, should be changed. If an oil
change is needed.
9) Remove the screws that hold the oil chamber cover in place & remove
the oil.
10) Replace the mechanical seal if necessary.
11) Replace the oil.
12) Assemble the pump.
STATOR REPLACEMENT OR ELECTRICAL REPAIR
The BJM Pumps
®
“F” Series designed pumps utilize unique construction methods and
materials. The interconnection of all wiring requires the use of a BJM
Pumps®
wire
connection kit. Included in this kit are specific instructions on how a qualified factory
trained and certified repair technician can perform this work properly. No other materials
or methods should be used on this product.
Summary of Contents for FAHRENHEIT SK-F Series
Page 11: ...12 Figure 1 SKX750F 115 control Figure 2 SKX750F 230 SK1500 230 and SKX1500 230 control...
Page 15: ...16 EXPLODED VIEW OF SK1500C F...
Page 16: ...17 EXPLODED VIEW OF SKX750CSS F SKX1500CSS F...
Page 19: ...20 SINGLE PHASE WIRING DIAGRAM 115V 230V MODELS SK1500CF SKX750CSS F SKX1500CSS F...
Page 25: ...NOTES...
Page 43: ...18 EXPLODED VIEW OF SK08C F SK15C F...
Page 44: ...19 EXPLODED VIEW OF SKX08CSS F SKX15CSS F...
Page 45: ...20 EXPLODED VIEW OF SK22C F SK37C F...
Page 46: ...21 EXPLODED VIEW OF SKX22CSS F SKX37CSS F...
Page 47: ...22 EXPLODED VIEW OF SK55C F SKX55CSS F SK75C F SKX75CSS F...
Page 48: ...23 EXPLODED VIEW OF SK110C F SKX110CSS F SK150C F SKX150CSS F...
Page 58: ...33...
Page 63: ...NOTES...