SPP-R200II Command Manual
Rev. 1.00
BIXOLON
- 16 -
ESC SP
Function:
Set the character right space
Code:
ASCII
ESC
SP
n
Hex
1B
20
n
Decimal
27
32
n
Range:
0 ≤ n ≤ 255
Default:
n=0
Description:
■
This command sets the size of space to right of character.
•
Right space = n × [horizontal motion units].
Remarks:
■
In a double width mode, the right space will be doubled.
■
Horizontal motion unit varies depending the printer model.
Differences:
■
Horizontal motion unit: 0.125mm(1/203 inch)