SPP-R200II Command Manual
Rev. 1.00
BIXOLON
- 104 -
<Function 50> BS ^ L pL pH fn (fn=2, 50)
Code:
ASCII
GS
(
L
pL
pH
m
fn
Hex
1D
28
4C
pL
pH
m
fn
Decimal
29
40
76
pL
pH
m
fn
Range:
(pL + pH x 256) = 2 (pL=2, pH=0)
m=48, fn=2, 50
Default:
None
Description:
This command prints the graphics data defined by the process of Function 112.
Remarks:
■
The graphics data stored in the printer buffer is printed.
■
This command is available in standard mode, not in page mode.
■
The graphics data is defined by Function 112.
■
The required amount of line feed pitch is used for printing graphics data, regardless of the existing setting value of the
pitch.
Differences:
■