Rev. 1.01
- 61 -
SMP6210
15. Frame Ground
It is advisable to connect the printer body and the platen roller block to the FG (frame
ground) of the outer case to prevent damage to the thermal head by static electricity.
Check performance by actually using the device.
15-1 Frame ground connection method
- Connect the frame ground (FG: Terminal No.8, 9) of FPC Cable (50-pin) to frame ground
(FG) or outer case.
- Make the distance between the FG of FPC Cable (50-pin) and FG or outer case as short
as possible.
- Use metal screws (nickel coated screws and start washers) to connect the platen roller
block to the FG of outer case.
- Electric potential of all frame ground must be the same.
- Depending on the operating conditions, connect the GND terminal (SG) to FG, or put a
resistor of 1M
Ω between GND terminal (SG) and FG.
16. Auto Cutter Error Handling
All error handling of the printer mechanism checks the ON signal of the cutter home switch
with highest priority and handles this error first. If this routine is not applied, it may cause
fatal problems to the printer mechanism due to overheating of step motor.
Summary of Contents for SMP6210
Page 1: ...User s Manual SMP6210 Thermal Printer Mechanism Rev 1 01 http www bixolon com...
Page 16: ...Rev 1 01 16 SMP6210 2 Disassembly diagram...
Page 23: ...Rev 1 01 23 SMP6210 5 4 Dimensions of thermal device...
Page 45: ...Rev 1 01 45 SMP6210 Fig 8 2 Dimension related to mounting...
Page 66: ...Rev 1 01 66 SMP6210 Mechanical Device Assembly Including Platen Roller Block...