background image

 

www.bitrek.com.ua  
[email protected] 
+380 44 507 02 07

 

The  body  of  the  device  contains  grooves  for  easy  fastening  with 

plastic ties. 

 

Electrical connections

 

Power  supply  wires  are  laid  through  the  maintenance  holes  in  the 

body  of  the  vehicle  from  the  regular  battery  location  to  the  place  of 
installation  of  the  tracking  device.  Power  wires  are  connected  to  the 

corresponding battery terminals. 

 

Carrying  out  welding  work  during  the  repair  of  the  vehicle 

necessarily requires disabling of power socket and peripherals. 

 

The active state for the discrete inputs with active "1" is to supply 

to these inputs the voltage exc 8 V. The passive state for these 

inputs is the lack of connection ("in the air" input). 

Analog input voltage can range from 0 V to 27 V. 
The  discrete  outputs  of  the  device  are  made  according  to  the 

scheme such as "Open collector". The load shall be connected to the gap 

between  the  discrete  output  and  "+"  power  of  the  on-board  network. 
When  activated,  the  output  gets  ground  switching.  Maximum  current  of 

the discrete output load shall not exceed 0.5 A. If it is needed to switch 
higher currents, connect digital outputs via additional relay. 

 

 

Analogue input voltage shall not exceed 27 V.  

 

Device  supply  voltage  shall  not  exceed  36  V.  Otherwise  the 

device may be put out of action

 

Device to computer connection 

The tracking device can be connected to a PC, in order to configure 

the  device,  as  well  as  to  perform  maintenance  works.  For  this  purpose, 
the  device  is  equipped  with  a  service  UART  output.  To  connect  to  a 

computer,  use  an  additional  USB-UART  converter,  which  can  be 
purchased from a dealer for an additional fee. 

UART output socket is located on the board of the device. To access 

the  socket,  remove  the  cover  of  the  device.  Procedure  of  connection  of 
USB-UART converter cable is shown in Figure 3. 

Summary of Contents for BI-868 TREK HW2

Page 1: ... Kyiv MFI 380333 tax number 163033726585 www bitrek com ua sales bitrek com ua 380 44 507 02 07 95 S Vidradniy avenue Kyiv Ukraine 03061 Phone 38044 507 02 07 Fax 38044 507 02 02 www bitrek com ua sales bitrek com ua Vehicles Tracking Device BI 868 TREK HW2 Operating manual Version 2019 11 1 ...

Page 2: ... 6 SIM card installation 6 Connector for power supply and peripherals 7 Assembly commissioning 7 Assembly recommendations 7 Electrical connections 8 Device to computer connection 8 Description of indication elements 9 Adjustment of BI 868 TREK HW2 device 10 Basic information 10 List of information commands to operate the device 11 List of control commands to operate the device 13 Basic configurati...

Page 3: ...necting disconnecting the power socket and inputs outputs turn off the power supply Transportation and storage Transportation of tracking device in the transport packaging of the manufacturer is allowed by all kinds of enclosed land and sea transport rail cars containers vehicles of closed type bilges etc Transportation in pressurized heated compartments of the aircraft is allowed Transportation a...

Page 4: ...n principles In real time mode the tracking device determines location and movement parameters of the object time geographical coordinates speed and direction collects and processes information from the analog and discrete sensors ensures control over actuating mechanisms upon command from the control dispatching panel Received data are recorded and stored in an internal log which is implemented o...

Page 5: ...inputs 2 11 Voltage range of digital input From 0 V to 40 V 12 Type of digital output Open collector 13 Maximum load current of discrete output 0 5 A 14 Voltage range of analogue inputs From 0 V to 27 V 15 Power type Permanent 16 Internal battery 1000 mAh 17 Power supply From 9 V to 36 V 18 Average current consumption 12 V 60 mA 19 Maximum current consumption 12 V 350 mA 20 Volume of non volatile ...

Page 6: ...th the following set 1 Tracking device BI 868 TREK HW2 1 piece 2 Connection cable 1 piece 3 Technical datasheet 1 piece 4 Warranty card 1 piece 5 Package box 1 piece Preparation for operation commissioning SIM card installation To operate in GSM network device shall contain installed SIM card of Micro SIM format Phonebook of SIM card shall remain empty PIN code shall be removed use of SIM card wit...

Page 7: ...ontact elements No Color Contact name Signal type Contact assignment 1 Violette Out Output Digital output 2 Blue DAT_high Input Digital input with active 1 Reserved for Ignition signal 3 Black GND Power supply Common cable ground 4 White AN_in 1 Input Analogue input No 1 5 Grey AN_in 2 Input Analogue input No 2 6 Red V_in Power supply onboard power supply rated voltage 12 V or 24 V Assembly commis...

Page 8: ...ording to the scheme such as Open collector The load shall be connected to the gap between the discrete output and power of the on board network When activated the output gets ground switching Maximum current of the discrete output load shall not exceed 0 5 A If it is needed to switch higher currents connect digital outputs via additional relay Analogue input voltage shall not exceed 27 V Device s...

Page 9: ...ntrol Once connected the device will transmit data about its state to the terminal In addition the user is able to use a terminal program to send commands to a device and receive response to them Send preliminary to device the password to access the terminal in the following format TPASS password where password is a password for access to the device terminal default value is 11111 Lifetime of acce...

Page 10: ...ing ways 1 With a direct connection of the device to a computer 2 Remotely using SMS commands 3 Remotely using the configuration server Setting of the device through any of the available methods is limited with the setting of the required values of the device parameters Each parameter has its own unique ID Special commands are used to read record the values of selected parameter At remote configur...

Page 11: ... of the device Command to be sent getstatus Example of response Data Link 1 GPRS 1 IP xxx xxx xxx xxx GSM 4 Roaming 0 where Data link current state of connection 0 not connected to server 1 connected to server GPRS status GPRS 0 not active 1 active IP IP address of the device with an active GPRS connection it is assigned by the operator not to be confused with the IP address of the server GSM leve...

Page 12: ... BI 868v4 Ver 2 9 2 Read the values of the device s internal sensors Command to be sent getio Example of response DH1 0 DO1 0 VPSV 12996mV AIN1 37mV AIN2 38mV where DH1 0 current state of the discrete input DO1 0 current state of the discrete output VPSV external power supply millivolts VBAT internal battery voltage millivolts AIN1 37mV AIN2 38mV analog inputs voltage millivolts Request of device ...

Page 13: ...e of response Param ID Val where Param ID ID of requested parameters Val current value of parameter Example of the command to request APN of the device a parameter that contains the APN device has ID 0242 getparam 0242 Example of response Param ID 0242 Val gps utel ua List of control commands to operate the device Table 5 List of control commands No Command Description Availability of response 1 c...

Page 14: ...the parameter by ID Command to be sent setparam Parameter ID consists of four digits and indicates the number of the parameter All configurable parameters are specified in the list of device parameters see Appendix 1 and Appendix 2 Example of response Param ID New Val where Param ID ID of parameter to be set up New Val assigned value of parameter Example of the command to set APN of the device a p...

Page 15: ...ut Out 1 setdigout 1 The first digit in the command is Out 1 output state When it is necessary to activate the output set the output value must to 1 When it is necessary to deactivate the output set the value to 0 Activate deactivate the safety locking of ignition Command to activate safe locking ignitionon Command to deactivate safe locking ignitionoff In case of activation of secure locking the ...

Page 16: ... ID 0910 see Appendix 1 Format of sending a standard password to the device TPASS 11111 Examples of response TASK COM TERM PASSWORD OK correct password is entered TASK COM TERM INCORRECT PASSWORD incorrect password is entered When sending commands via SMS set the login and password of SMS access To set the login use ID 0252 parameter to set the password use ID 0253 To set the login and password an...

Page 17: ... parameters for setting For example to set the value of power supply voltage level to the server use group of parameters of 0410 0411 0412 0413 0414 0415 These options have the following structure 0410 0411 0412 0413 0414 0415 First 3 numbers green refer to parameter group number to configure the I O element Last number gray is a parameter number 6 parameters from 0 to 5 are available for a single...

Page 18: ...e the input value to a predetermined value 8 generation of the event to change the input value to a predetermined value monitoring 5 Averaging constant From 0 and higher Notes to Table 5 Parameter 0 on off of transmission of I O element to the server Parameter 1 Priority low high While selecting Priority low data of the sensor will be sent to the server with the following data packet While selecti...

Page 19: ...0 mV Lowering the voltage below 10 V will generate the event see Figure 4 PSV U mV t s 10 000 Figure 4 Generation of event by returning to the range 1 Leaving the range The event will be generated if the actual sensor value is outside the predetermined range Example The lower voltage limit is set to 0 the upper limit is set to 10 V 10 000 mV Rising of the voltage above 10 V will generate the event...

Page 20: ...the actual value of the sensor starts to be transmitted to the server in the monitoring mode 6 Monitoring returning leaving to of the range When one of the events is generated the actual value of the sensor starts to be transmitted to the server 7 Change of the input value to a predetermined value Changing of the input value to the predetermined value in either direction will cause the event gener...

Page 21: ...end SMS shall be defined as a trigger for outgoing SMS messages In addition to the SMS message you can add customized text where the text length shall not exceed 30 characters in the Latin alphabet Roaming options The tracking device BI 868 TREK HW2 is able to operate in two modes in the home network mode and in the operating mode with a predetermined list of authorized operators Operation mode is...

Page 22: ...er 1111 ipsHost1 0188 string IP address of backup server 193 193 165 165 ipsPort1 0189 2 byte PORT of backup server 20127 ConfServEna 0908 1 byte Operation with the configuration server 0 disabled 1 enabled 1 settingsHost 0220 string IP or DNS of WEB configuration server configurator bitrek com ua settingsPort 0221 2 byte PORT of WEB configuration server 55755 settingsTimeOut 0222 2 byte Period of...

Page 23: ...econd 300 Switching Host 2 Port 2 0196 1 byte Permission to use backup server 0 ProtocolType 0241 1 byte Type of data transfer protocol to the server 0 Teltonika 1 IPS 0 GPRSRegTimeout 4018 2 byte GPRS network registration timeout second 120 GSMRegTimeout 4019 2 byte GSM network registration timeout second 120 Tracking Enable Time Period 0900 1 byte Permission to record by time 1 Enable Dist Perio...

Page 24: ...m Time 0357 1 byte Time to wait for a response from the server second 60 Delta X 0281 1 byte Angle of deviation of the accelerometer by X axis degree 3 Delta Y 0282 1 byte Angle of deviation of the accelerometer by Y axis degree 3 Delta Z 028З 1 byte Angle of deviation of the accelerometer by Z axis degree 3 Start Move Timeout 0284 2 byte Timeout of movement start according to the accelerometer 0 ...

Page 25: ... 2 byte Timeout of sleep mode by accelerometer min 720 GPS GNSS 4016 1 byte Type of positioning system used 3 Security Phone0 0261 string Authorized telephone number 0 Phone1 0262 string Authorized telephone number 1 Phone2 0263 string Authorized telephone number 2 Phone3 0264 string Authorized telephone number 3 Phone4 0265 string Authorized telephone number 4 Phone5 0266 string Authorized teleph...

Page 26: ...llation of PIN code of SIM card operator Jamming Jamming Level 0806 1 byte Level of detection of jamming event c u 80 JammingEna 0807 1 byte Permission to send SMS about jamming 0 disabled 1 enabled 0 Service Reboot Per 0186 1 byte Period of the regular reboot of the device hour 24 Reboot Type 0187 1 byte Type of device reset 0 full 1 only modem 0 ErrSatNum 0992 1 byte Authorization to set the num...

Page 27: ...ing voice call SMSTrigger 0816 2 byte ID of I O element trigger to send an SMS to authorized phone number when the events occur SMSText 0817 string Text added to the SMS no more than 30 characters in the Latin alphabet Roaming Operator selection 0917 1 byte Operator selection mode 0 UsipTable 0020 0057 string List of codes of authorized operators UsAPNTable 0060 0097 string List of APN of authoriz...

Page 28: ...ts setting K_AIN1 0957 2 byte Kalman coefficient for the analog input No 1 filtering 1 off 2 65535 c u 19 K_AIN2 0958 2 byte Kalman coefficient for the analog input No 2 filtering 1 off 2 65535 c u 19 Ain1Per 0959 1 byte Coefficient of median filtering for analog input No 1 from 1 to 256 c u 19 Ain2Per 0980 1 byte Coefficient of median filtering for analog input No 2 from 1 to 256 c u 19 ...

Page 29: ...11 0512 0513 0514 0515 State of motion Possible values 0 1 2 3 0 no movement 1 motion detected by accelerometer 2 motion detected by GPS more than 10 km h speed detected over 10 sec 3 motion detected by accelerometer and GPS 6 realOdometr 199 0500 0501 0502 0503 0504 0505 Relative odometer 7 Odometr 200 0710 0711 0712 0713 0714 0715 Absolute odometer 8 GPSPower 69 0450 0451 0452 0453 0454 0455 Ava...

Page 30: ...tus unknown 5 roaming 13 GPRS net stat 119 0770 0771 0772 0773 0774 0775 Registration status in the GPRS network 0 not registered and not searching for carriers 1 home network 2 not registered but searching for carriers 3 registration disabled 4 status unknown 5 roaming 14 GPRS content stat 120 0780 0781 0782 0783 0784 0785 Activation status of GPRS content 0 not activated 1 activated 15 SIM stat ...

Page 31: ...orner acceleration 26 HDOP 122 0800 0801 0802 0803 0804 0805 Reduced accuracy in the horizontal plane 27 iMCC mcc 4010 4011 4012 4013 4014 4015 Positioning by base stations 28 iMNC mnc 4020 4021 4022 4023 4024 4025 Positioning by base stations 29 iLAC lac 4030 4031 4032 4033 4034 4035 Positioning by base stations 30 iCellID cell id 4040 4041 4042 4043 4044 4045 Positioning by base stations 31 Rx l...

Page 32: ...32 www bitrek com ua sales bitrek com ua 380 44 507 02 07 Document version Date Document version Note 26 11 2019 2019 11 1 Basic document ...