Preliminary
Synchronizing Acquisition, Camera, CTABs and External Signals
The Karbon
KBN-2-24
BitFlow, Inc.
Version F.0
HCOUNT Release From Zero
This operation controls the behavior of HCOUNT when it reached zero (see Table 2-
16).
HCOUNT Reset To Zero
This operation controls how HCOUNT is reset to zero (see Table 2-17).
Note: The HCOUNT can always be reset by RST_SW or HOST_WCMD_ABORT
HCOUNT Release From Stick Point (1FF0h)
This operation controls the behavior of HCOUNT when it hits the stick point. The pur-
pose of the stick point is to allow for very long periods of time between lines. The stick
point is located at 1ff0h. See Table 2-18.
Table 2-16 HCNT_RLS_ZERO
Initiator
HCNT_RLS_
ZERO
Comments
None
0
Normal operation mode, no stop at zero
ENC_ASRT
1
One-shot mode, wait for encoder for
release
Table 2-17 HCNT_RST
Initiator
HCNT_RST
Comments
END_OF_HAW
0
Default operation, end of HAW
FEN_ASRT or RST_
HCTAB
1
Reset on FEN_ASRT, Random FEN mode
RST_HCTAB
2
Reset from HCTAB
Table 2-18 HCNT_RLS_STK
Initiator
HCNT_RLS_STK
Comments
None
0
Normal operation mode, no stop at
1FF0h
HLOAD or HRESET
1
Stay at x1FF0 till load (usually LEN) or
reset asserted
Summary of Contents for KBN-CL4-2.51-SP
Page 20: ...P r e l i m i n a r y The Karbon CL Models The Karbon KBN 1 12 BitFlow Inc Version F 0 ...
Page 62: ...P r e l i m i n a r y DEST_ADD The Karbon KBN 3 8 BitFlow Inc Version F 0 ...
Page 190: ...P r e l i m i n a r y Camera Link Controls CCs The Karbon KBN 7 12 BitFlow Inc Version F 0 ...