IMPORTANT
This radiator is equipped with a resistance which has an integrated power shut-
off and fuse. Using the radiator without water will permanently damage the fuse as well as
the resistance. In this case it must be changed though "
not under the manufacturer’s gua-
rantee
". Using the radiator only partially filled with water causes the heating function to shut
off automatically. Alternate function will continue as long as the main heating section is not
properly filled.
If you notice that the electrical part of your towel dryer is activated, but that it fails to heat up
inspite of thermostat demand or positive working operation, carry out the following operations:
1) Ascertain that your radiator is full of water (see
paragraph B
).
2) Press on the key of the remote control for 2 seconds (see
chapter 5.1
) to stop the electrical
operation of the appliance for 30 to 60 minutes. This operation is necessary to cut off the thermal
safety device.
3) Press the key again for 2 seconds: the radiator is ready to heat up properly.
4. Putting the remote control into service
mode
mode
mode
mode
mode
The time setting screen is displayed, showing 00:00. Press and hold the
+
or
-
keys, to set
the time quickly.
During initialisation: pressing
P1P2
takes you back to the previous screen.
Then proceed to set the day of the week:
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
1
Monday
5 Friday
2
Tuesday
6
Saturday
3
Wednesday
7
Sunday
4
Thursday
(for example)
You then proceed as described in
chapter 4.1
to ensure your
appliance works correctly.
4.1 Initialization