5.Turn the unit on by moving the ON/OFF switch to the ON position.
6. Allow the sprayer to run for 15-30 seconds to flush the test fluid out through the return hose and into the
waste container.
7. Turn the unit off by moving the ON/OFF switch to the OFF position.
Preparing to Paint
Before painting, it is important to make sure that the fluid in the system is compatible with the paint that is
going to be used.
NOTE: Incompatible fluids and paint may cause the valves to become stuck closed, which would require
disassembly and cleaning of the
Sprayer’s fluid section.
1. Place the suction tube into a container of the appropriate solvent. Examples of the appropriate solvent are
water for latex paint or mineral spirits for oil-based paints.
2. Place the return hose into a metal waste container. 3.Set the pressure to minimum by turning the pressure
control knob to the ”Min”
4. Move the PRIME/SPRAY valve down to the PRIME position.
5. Turn the unit on by moving the ON/OFF switch to the ON position.
6. Allow the sprayer to run for 15¨C30 seconds to flush the old solvent out through the return hose and into
the metal waste container.
7. Turn the unit off by moving the ON/OFF switch to the OFF position.
NOTE: Make sure that the spray gun does not have a tip or tip guard installed.
8. Move the PRIME/SPRAY valve up to the SPRAY position.
9. Turn the unit on.
10. Unlock the gun by turning the gun trigger lock to the unlocked position.
Ground the gun by holding it against the edge of the metal container while flushing.
Failure to do so may lead to a static electric discharge, which may cause a fire.
11. Trigger the gun into the metal waste container until the old solvent is
gone and fresh solvent is coming out of the gun.
12. Lock the gun by turning the gun trigger lock to the locked position.
13. Set down the gun and increase the pressure by turning the pressure control knob slowly clockwise.
14.Check the entire system for leaks. If leaks occur, follow the”Pressure Relief Procedure” in this manual before
tightening any fittings or hoses.
15.Follow the “Pressure Relief Procedure”in this manual before changing from solvent to paint.