Bird Pulse Power Sensor 7027
12
Specifications
Frequency
Varies by model, See
.
Power Range
(Continuous Average Power)
Varies by model, See
.
Peak Power
@ 60% Duty Cycle
Varies by model, the peak power is the upper end of
the power range. See
.
Measurement Type
Thru-Line Power
Impedance, nominal
50 Ohms
Average Power
Range
Accuracy
Varies by model, See
.
1% at calibration frequencies
2% at all other frequency within the sensor
bandwidth
VSWR Range
1.0:1 to 2.0:1
Gated Average Power
Accuracy
1% at calibration frequencies
2% at all other frequency within the sensor
bandwidth
Insertion loss, Max
<0.05 dB
Insertion VSWR, Max
1.05
RF Connectors
QC (Overall power will be limited by connector
selection.) See
for QC connectors supplied by model
number.
Directivity, Min
28 dB
Sync Input
Input port impedance
Input level Pulse ON
Input level Pulse OFF
>10 kOhms
TTL High (2.0 V - 5.0 V)
TTL Low (0 V - 0.85 V)
Factory Calibration
NIST Traceable
Recommended Calibration Cycle 6 Months
Field Calibration
None
Interface Options
USB 2.0
Ethernet
Power Supply
Via USB, for USB only models (less than 0.5A at 5V)
Via 5V AC/DC Power Supply (supplied) for Ethernet
models