Bird Pulse Power Sensor 7027
8
Power Requirements
The Ethernet model Pulse Power Sensor operates on 5 VDC power input
provided by the AC adapter supplied with the sensor.
IP Address
The Ethernet address for the Pulse Sensor may be set to any address required
for the monitoring/controlling system.
Default IP Address:
IP Address: 192.168.2.151
Netmask: 255.255.255.0
Gateway: 192.168.10.1
Note:
To reset the sensor’s Ethernet address to default, press and
hold the Ethernet reset pushbutton for five seconds.
IP Address Configuration
Note:
To change the sensor’s IP address, the PC connected to the
Power Sensor must be on the same subnet.
1.
Connect an Ethernet cable to the PC.
2.
Connect the remaining end of the Ethernet cable to the power sensor.
3.
Open a web browser on the PC.
4.
Type the Sensor’s default IP Address into the browser’s address box, then
press Enter.
Figure
6
Pulse Sensor Configuration Menu
5.
Click Network Configuration once the Pulse Sensor’s configuration menu is
displayed.
6.
Type in the new IP Address, netmask, and Gateway, then click Submit.
Figure
7
IP Address Configuration Menu