Loop detector for industrial doors and gates and car parks
Translation of the original instruction
General
1
Safety instructions
3
Connect electrical equipment
2
Mechanical mounting in the switch cabinet
En
GL
iS
h
354822B
06/16
i
Information – light emitting diode
LCD display
“Mode” key
“Data” key
Connecting terminals
Type plate
– These devices and their accessories may only be operated in accordance
with the operating instructions (intended use).
– These devices and their accessories may only be placed in operation by
trained and qualified personnel.
– These devices may only be operated with the operating voltages and
parameters intended for them.
– If malfunctions occur that cannot be eliminated, place the device out of
operation and send it in for repair.
– These devices may only be repaired by the manufacturer. Tampering and
alterations are not permitted. This will invalidate all guarantee and war-
ranty claims.
The ProLoop Lite is mounted in the switch cabinet on a 35 mm H-rail in accordance with EN 50022. The terminals can be plugged in and coded.
The loop connection wiring to a loop detector must be twisted at least 20 times per meter.
Please wire the device according to the wiring diagram.
Ensure correct assignment of the terminals and that the power supply is right in accordance with the type plate on the device.
Power supply
Loop connection
1-channel device
Loop connection
2-channel device
Output 1
Output 2
˜⁄
+
˜⁄
−
A1
A2
L3
L4
L3
L4
L5
L6
1
2
14
11
12
no
nc
common
24
21
22
no
nc
common
4
Value and parameter setting options
General
The settings of the ProLoop Lite devices in this chapter are depicted and explained using the 1-loop device.
The settings for loop 2 of a 2-loop device should be made using the corresponding method.
3.1
Terminal connection diagram