background image

4

Technical Data

1.   The warranty and liability of Bircher Reglomat AG are based on the sales contract.
2.   The warranty and liability shall expire prematurely, should the client or third parties not use 

and/or operate the product in compliance with existing operating instructions, should incorrect 
changes or repairs be made by the client or third parties, should the client or third parties, when 
a fault has occurred, not take suitable steps at once for a reduction of possible damage/losses 
and offer Bircher Reglomat AG a chance for remedying the said fault.

3.   The warranty and liability shall exclude any damage for which there is no proof that it is due to 

poor materials, faulty construction, poor workmanship, and any damage caused by other rea-
sons, for which Bircher Reglomat AG cannot be held liable.

4.   No liability can be assumed for any consequential damage, provided this is not governed other-

wise by applicable product liability laws and regulations.

5.   Warranty claims made against the seller on the basis of the sales agreement are not affected 

by these regulations.

6.   For the benefit of its customers Bircher Reglomat AG constantly develops its products further. 

Bircher Reglomat AG reserves the right to make changes to any of the products described in this 
document without prior notice.

Manufacturer: 

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen

Authorised rep: 

Bircher Reglomat GmbH, Robert Bosch Strasse 3,  

 

D-71088 Holzgerlingen

Following directives 

 

have been observed:  

MD 2006/42/EC, RoHS 2011/65/EU, EMC 2014/30/EU

EC type-examination 
certificate: 

In combination with Safety Edges

Notified inspection centre:  Suva, Bereich Technik, SCESp 0008, Kenn-Nr.1246
Product variants: 

ESA25-24VACDC, ESA25-230VAC, ESAS25-230AC, ESP25-24VACDC

Identification of the year of manufacture

Contact

EC-Declaration of Conformity

Bircher Reglomat AG

Wiesengasse 20

CH-8222 Beringen

www.bircher-reglomat.com

Warranty and liability





 



 





































 











































Year Month Day

2015 06 

05

94

J1

J2

LED1

1 2

8  7A

REL2

REL3

X1

X10

REL1

F1

76

LED2

LED4

    LED3

LED5

ESZS 25

Plug:  

Pin assignement

X1, X2 Output restart

X4, X5 Output safety

X7, X9 Power supply 24VAC

X3, X6, X8 Not assigned

X10 GND not contacting

1, 2 Signal transmitter

8, 7A Disconnect restart

Subject to change without notice

ESA 25 

ESP 25

ESZ 25

Housing 

ABS grey

– 

transparent cover 

– Dimensions 

– Protection Class 

– Cable gland 

 

80x110x65 

IP 65 

2xPG 7, 1xPG 9

70x94

IP 00

76x94

IP 00

Supply Voltage 

– 230VAC

– 115VAC 

– 24VADC 

– Frequency Range 

(+10/-20%)  

with isolating transformer

(+10/-20%)  

with isolating transformer

24VAC/24VDC (+10/- 10%)

50/60 Hz

Power Consumption 

max. 4VA

Sensor Inputs

– Input resistance 

–  Input voltage with 8.2kOhm 

5 kOhm to 12 V (internally)

approx. 7.5 VDC

Signal Output Relay

– Switching Capacity

– Reaction time (energize) 

– Reaction time (de-energize) 

2 A/250 VAC

< 30 ms

< 20 ms

Indicators 

– Operation 

– Safety Shutdown 

– Fault 

LED 3 mm

Green

Yellow (2 off)

Red (2 off)

Temperature Range 

–20°C to 55°C

Suplementary data

Function «Re-open»

ESAS 25

ESPS 25

ESZS 25

House

– Cable gland

look ESA

3xPG 7, 1xPG 9

Relay for Re-open function

– Switching Capacity

– Time Delay

– Impulse Duration 

2A/250VAC

1…1.5 sec

1,5…2 sec.

Connections, Component Layout

General

LED1  

Operating indicator (green)

LED2, LED4  Function indicator (yellow)

LED3, LED5  Fault indicator (red)

REL1, REL2   Switching relays, working contacts switched in series

F1  

Fuse 2A slow, relay contact protection

J1  

Test contact for REL1

J2  

Test contact for REL2

At ESAS, ESPS, ESZS

REL 3  

Switching relay working contact

J2 

Test contact for REL 2 and REL 3

J1

J2

REL2

X1

X10

REL1

F1

94

76

LED2

  LED4

    LED3

LED5

Plug:  

Pin assignement

X1, X2  Signal transmitter  

(IN; GND)

X4, X5 Output; Safety

X7, X9 Power supply 24VAC

X3, X6, X8 Not assigned

X10 GND not contacting

ESZ 25

LED1

LED1

1 2

J1

J2

REL2

REL3

REL1

TR1

F1

75
94

70

=

=

3   4

5 6

LED2
LED4

LED3
LED5

ESA 25, ESP 25

Wiring diagram:

3, 4 Safety circuit

5, 6 Supply

1, 2 Sensor

LED1

1 2

ESAS/ESPS

Wiring diagram:

3, 4 Sensor circuit

7, 8 Stop - Re-open

5, 6 Supply

1, 2 Sensor

J1

J2

REL2

REL3

REL1

TR1

F1

75
94

70

=

=

5 6

LED2
LED4

LED3
LED5

3   4

7  8 7A 8A

Reviews: