961203_02
N
L
54 52 51
Switch
english
33
5.2 Connecting diagram
51-54
Operational or fault
notification (switchable)
as closing contact:
Closes for faults/operating
contract load
max. 250 V~, 1 A
51-52
Operational or fault
notification (switchable)
as opening contact:
Opens for faults/operation
contact load
max. 250 V~, 1 A
Supply
~1
×
230 V
max. 250 V
1 A
Operational or fault notification (switchable)
as opening contact, opens for faults/operation
SWITCH
1
2
ON
Power limiting
Operating notification
ON
Terminals 51, 52, 54
OFF
Power limiting
Error message
OFF
Terminals 51, 52, 54
5.3 Performance limit
The p
red
output limitation reduces the pump performance
to 80% of the maximum capacity, to avoid feed noise
due to feed amounts that are too high.
min
max
P
red
960945
_
00
Delivery condition: see 7.7
Switch
ON
OFF
ON