BIOWAIR biow 100 User Manual Download Page 15

15

R

egeneration & 

L

ife  

02 

CRU BIOW OPERATION

2.7. NIGHT MODE 

The CRU Biow has an optical sensor that 

measures the amount of light in the room where 

the equipment is.  When the CRU Biow operates 

in night mode, it will operate normally, but the 

display will be dimmed. 

If the device detects a drop in the light level in 

the room, after 20 seconds, the display will shut 
down completely except for the symbol    and 

the symbol indicating the speed at which it is 

operating, since this will not change as it does in 

“AUTO” mode. 

This operating mode provides the user with an 

adjustment of the brightness of the equipment 

by dimming the brightness of the display, in 

addition to the subsequent shutdown of the 

display. 

NOTE: To light up the display once it is dimmed 
or turned off, simply press any of the buttons 
on the remote control, and the equipment will 
light up showing the parameters of the last 
selected program. 

2.8. MODO MANUAL

The CRU Biow allows full customization of its 

functionality: 

•  Selection of the air treatment speed: V Silent

, V White     , V2  y V3 .

•  Activation/deactivation of plasma ionizers 

(ION) to electropolarize suspended particles. 

•  Activation/deactivation of ultraviolet lights 

(UV).

•  Timer in case you want to temporarily limit 

its function. 

See summary table in section 2.4 PROGRAMMING 

AND FUNCTIONALITIES 

.

2.9. WIFI PROGRAMMING MODE

The programming mode, identified with the 

WIFI symbol, allows 100% customization of 

the CRU Biow functionality in within specific 

time slots, as well as controlling or modifying 

the programming of one or more CRU Biow, 

comfortably and from a single mobile device. 

In addition, it allows you to activate the +Protect 

function, which activates thermal treatment in 

sequential 10-minute tranches, for maximum 

protection against viruses and bacteria. 

To do so, you need to connect the CRU Biow 

via WIFI, installing the Biow APP. (See section 

4. BIOW APP – ON DEMAND PROGRAMMING).

Summary of Contents for biow 100

Page 1: ...USER MANUAL CRU BIOW Regeneration Life...

Page 2: ...Regeneration Life...

Page 3: ...AL 15 2 9 WIFI PROGRAMMING MODE 15 2 10 DISPLAY 16 2 11 SAFE EQUIPMENT SHUTDOWN 18 2 12 HOW TO OPTIMISE MY CRU BIOW 18 3 3 BIOW APP ON DEMAND PROGRAMMING 20 3 1 BIOW APPINSTALLATION 20 3 2 ON DEMAND P...

Page 4: ...l wear The device is not used by people with reduced physical sensory or mental capabilities Under no circumstances should the repair and internal handling of the device be carried out by staff who ar...

Page 5: ...use of the device by a person responsible for their safety Some parts of this product can get hot and cause burns Special attention should be paid when children and vulnerable people are present The d...

Page 6: ...20 kg We recommend not to place real flowers or other materials that may contaminate the air supply with pollen or other compounds 1 2 EQUIPMENT PARTS 1 Storage shelf 2 Manual ON OFF button 3 Display...

Page 7: ...degree of protection IP 21 Maximum power 500W Operating mode Continuous MATERIALES Lower part High quality steel Upper part Compact high strength silicon CRU BIOW 100 MEASUREMENTS AND WEIGHTS Model de...

Page 8: ...ent operating temperature 10 40 C Ambient storage transport temperature 0 45 C Relative air humidity 35 75 non condensing Air pressure 700 1060 hPa CRU Biow has an integrated base that enables you to...

Page 9: ...the equipment to the wall as shown in the figure 2x Measurements to attach to the wall the CRU Biow 100 Minimumground clearance 850 mm Measurements to attach to the wall the CRU Biow 60 Minimumground...

Page 10: ...will light up and from this moment on the equipment will be controlled by the remote control IMPORTANT Once the equipment is connected to the network ensure that the ON OFF switch remains easily acce...

Page 11: ...te control until AUTO appears on the display To change speeds you must exit the AUTO mode From this moment on Biow can be operated autonomously regulating itself according to the level of contaminatio...

Page 12: ...he level of particles and the light intensity of the room If there is light Speed according to need depending on the concentration of particles in the room ION UV selectable If there is not enough lig...

Page 13: ...tes the activation and deactivation of the ultraviolet lights These work by increasing the elimination of microorganisms In AUTO mode they will be deactivated during the night TIMER Facilitates the ac...

Page 14: ...that measures the amount of light in the room thus adapting its functionality to promote rest Speed with automatic adjustment according to the suspended particle concentration If the suspended particl...

Page 15: ...light up showing the parameters of the last selected program 2 8 MODO MANUAL The CRU Biow allows full customization of its functionality Selection of the air treatment speed V Silent V White V2 y V3...

Page 16: ...eneration Life 02 CRU BIOW OPERATION 2 10 DISPLAY Thermal treatment Heat mode Filter pack change message Ionization Ultraviolet light External temperature reader Operating mode Timer Speed Number of s...

Page 17: ...shows the number of suspended particles in the room and this in turn indicates the air quality of the room which is shown with the acronym BPR Blood Pollution Risk It allows you to select different pa...

Page 18: ...h hormones To increase the effectiveness of the CRU Biow it is recommended to place it on a flat surface ideally located in front of the bed and at the foot of the bed at the height of the mattress so...

Page 19: ...ting it during the night 1 2 Particularly sensitive people may experience certain unpleasant sensations such as slight nasal obstruction or a scratchy throat If this happens temporarily disconnect the...

Page 20: ...pment is powered on 2 Access the Biow application by downloading it from the App Store or Play Store In one simple step create your Biow account username and password which you can access from differe...

Page 21: ...this procedure may change depending on the type of mobile but in any case you must do it from the WIFI settings 4 Press the UV button for three seconds From the remote control of your CRU Biow until...

Page 22: ...image below so that it will be reset when searching The Biow network may require1minute to appear NOTE Reset the equipment for 10 seconds unplugging it from the socket to start the process again if a...

Page 23: ...works will be displayed Select the network you are interested in and the corresponding password will be included if the network is open the Confirm button will be pressed without including any type of...

Page 24: ...t the WIFI symbol is no longer flashing or crossed out 11 You can start now Program your Biow CRU in a fully personalized way and monitor its activity from the Biow APP From here you will be able to c...

Page 25: ...e from the physical remote control 2 We will also be able to access the programming from the upper right button 3 Once this button has been pressed a menu will appear where the operating mode of the C...

Page 26: ...unit wiring and external air is recommended If you detect damage deformation or rupture of any of these elements please contact with your distributor or contact Biowair Total Technical Service System...

Page 27: ...ss so you can dismantle the filter pack yourself by fully unscrewing lateral knobs located at the bottom of the unit Take the filter pack out of the casing Remove the black pre filter fixed with velcr...

Page 28: ...ilization system in heat mode The CRU Biow incorporates a pre filter that can be easily washed Only water should be used to clean this filter and dry it completely before replacing it in the equipment...

Page 29: ...ono Industrial Roces C Michel Faraday n 75 naves 9 y 10 33211 Gij n Asturias ESPA A www biow es 5 2 SPARE PARTS AND ACCESSORIES You can purchase them through your distributor or by calling customer se...

Page 30: ...of the device negligence wear and tear breaks incorrect installation and incorrect power supply to the device This guarantee is also excluded if the product is used for any other purpose than the ind...

Page 31: ...subject to separate collection at the end of its life cycle This indication is valid for the device as well as for any equipment marked with this symbol Disposing of these devices correctly you will h...

Page 32: ...e in the room Press the button and you will see the thermostat temperature on the screen The protection of the heat generating resistors may be activated This can happen if the air outlet of the equip...

Page 33: ...k that the heat mode is not activated since for safety reasons the air flow is increased in this function by automatically changing to V White My equipment turns on and off automatically Check if you...

Page 34: ...gulations in force and especially to Seguridad Safety CEM EMC EN 60335 1 2012 AC 2014 A11 2014 EN 60335 2 30 2009 A11 2012 EN 60335 2 65 2003 A1 2008 UNE EN 55014 1 2008 ERR 2009 A1 2009 A2 2012 UNE E...

Page 35: ...REATMENT CONTINUOUS LAMINAR FLOW 24 7 LONG LIFE LEVITATION RESPIRATORY SWEEP HEAT MODE AUTO SENIOR MODE PRECALIBRATION AND PERMANENT AUTOCALIBRATION 100 SILENTMODE AIR FILTERING ODOR FREE SYSTEM WHITE...

Page 36: ...BIOWAIR TOTAL SYSTEMS S L Pol gono Industrial Roces C Michel Faraday n 75 naves 9 y 10 33211 Gij n Asturias SPAIN biow_oficial www biow es biow oficial biow oficial Ref 290721...

Reviews: