OPERATION
Menu / Return
OK / Enter
3.1
CONTROL KEYS & INDICATORS
- Enter or return to Menu
as ESC
- Save selection
- Confirm selection
Selections
- Display alternatives
- Select settings
00 : 00
Current time
Flow indicator
Blue LED Bar
Steady solid on - water flow detected.
Blue breathing - standby, no flow detected and the
light will extinguish after 3 minutes.
Flow control
indicator
Blue LED
Flow switch activated - the unit
is
under flow-start operation.
Timer control indicator
Blue LED
Timer switch activated - the unit
is under timer-control operation.
Dosage level indicator
Blue LED
100% dissolved ozone performance.
(50% as standard when off).
Operation indicator
Green LED
Dissolved ozone dosage is
activated.
Alarm indictor
Yellow LED
Slow blinking - system error detected
in POST (Power On Self Testing).
Fast blinking - system error detected
while the unit is on duty.
Steady solid on - replace cell
cartridge now.
※
: For detail regarding all error
codes,
refer to Troubleshooting in
Section 5.
!
NOTICE
In control mode "Combo", both Flow Control and Timer Control indicators
are on, meaning Combo Control is activated and the operation of the unit is
guarded by both flow and timer settings. The generator only works when flow
and timer settings are given to meet requirements.
+