Biosan UVR-M User Instructions Download Page 9

7. 

Ordering information 

7.1 

Models and versions available: 

Model 

Version 

Description 

Catalogue number 

UVR-M 

V.4AA 

230 V, 50 Hz, EU plug (type E/F) 

BS-040105-AAA 

V.4AB 

230 V, 50 Hz, UK plug (type G) 

V.4A3 

230 V, 50 Hz, AUS plug (type I) 

V.4AC 

120 V, 60 Hz, US plug (type B) 

UVR-Mi 

V.3AA 

230 V, 50 Hz, EU plug (type E/F) 

BS-040110-AAA 

V.3AB 

230 V, 50 Hz, UK plug (type G) 

V.3A3 

230 V, 50 Hz, AUS plug (type I) 

7.2 

To inquire about or order the optional accessories, contact Biosan or your local Bio-
san representative. 

7.3 

Optional accessories: 

Optional accessory 

Catalogue number 

UVR-S movable support stand 

BS-040105-AK 

8. 

Care and maintenance 

8.1 

Service

.  

8.1.1  If the unit is disabled (e.g., lamp or fans not working, no reaction to key presses, etc) 

or requires maintenance, disconnect the unit from the mains and contact Biosan or 
your local Biosan representative. 

8.1.2  All maintenance and repair operations (except listed below) must be performed only 

by qualified and specially trained personnel. 

8.1.3  Operating integrity check. If the unit follow the procedure described in section 

5. Op-

eration

then no additional checks are required. 

8.2 

Cleaning and disinfection

8.2.1  Use mild soap and water with a soft cloth or sponge for cleaning the exterior. Rinse 

remaining washing solution with distilled water. Wipe dry the excess water with clean, 
soft cloth or sponge. 

8.2.2  Dust filter control/replacement. The dust filters on either end of the UV-recirculator 

should be checked monthly and cleaned or replaced when they become clogged. To 
check, replace or clean the filters, simply unclip the covers (fig. 4/

 and 5/

), if nec-

essary, fit a new one; otherwise rinse in water, dry, and set up existing filters. Clip 
covers back in place. 

8.2.3  To disinfect the exterior plastic parts, use 75% ethanol or DNA/RNA removing solution 

(e.g., Biosan 

PDS-250

). After disinfecting it is necessary to wipe the surfaces dry. 

8.2.4  Cleaning of the interior. Cleaning of the interior must be performed only by qualified 

and specially trained personnel. In order to ensure proper efficiency in the long run, 
it is recommended to clean the UV-recirculator once a month. 

8.2.5  The unit and its accessories are not autoclavable. 

Summary of Contents for UVR-M

Page 1: ......

Page 2: ...services we would like to hear from you Please send all feedback to Manufacturer SIA Biosan Ratsupites iela 7 k 2 Riga LV 1067 Latvia Phone 371 674 261 37 Fax 371 674 281 01 https biosan lv Marketing...

Page 3: ...special attention to sections marked by this symbol Caution Do not switch on the unit with the cover removed or without filters UV lamp must be covered at all times during operation Otherwise UV lamp...

Page 4: ...specific at mospheres Do not operate the unit if it is faulty or has been installed incorrectly Do not use outside laboratory rooms 2 4 Biological safety The user is responsible to carry out appropri...

Page 5: ...t damage Warranty covers only the units transported in the original package 4 2 Complete set Package contents 4 2 1 Standard set UVR M UVR Mi UV Cleaner Recirculator 1 pce Spare dust filters 2 pcs Spa...

Page 6: ...ta given by the manufacturer so lamp replacement or air recircu lation time extension by 12 is recommended in order to achieve the de sired air cleaning result Figure 4 UVR M overview 5 1 Working with...

Page 7: ...the next parameter 5 2 3 3If no key is pressed for more than 10 s the changes will be saved 5 2 4 The unit can operate in automatic or manual modes 5 2 4 1Manual mode Press the Run Stop key fig 5 7 to...

Page 8: ...nd maximum rel ative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C Biosan is committed to a continuous programme of improvement and reserves the right to...

Page 9: ...rating integrity check If the unit follow the procedure described in section 5 Op eration then no additional checks are required 8 2 Cleaning and disinfection 8 2 1 Use mild soap and water with a soft...

Page 10: ...y Medium 8 5 Decommissioning of the unit The user is responsible for the decontamination of the unit before decommissioning Dispose of the appliance as electronic equipment in accordance with the rele...

Page 11: ...and retain for your records Model Serial number Date of sale UVR M UVR Mi UV Cleaner Recirculator 10 8 Production date Production date is placed in the serial number on the label of the unit Serial n...

Page 12: ...SIA Biosan R tsup tes iela 7 k 2 Riga LV 1067 Latvia Phone 371 67426137 Fax 371 67428101 https biosan lv Edition 3 4 01 October of 2021...

Reviews: