DVT12T3
-
46
-
Extra error code shown on
ONE DOWN
/
SYSTEM DOWN (Drive error)
Hardware Error
Software Error
r
IDE register read / write
U
undefined command error
A
disk dma time out ? no pend in exe auto
E
chip busy soft error
B
bad block detected
C
uncorrectable error detected
D
data transfer requested
E
IDE drive busy in start
I
ID not found
M
data address mark not found
N Disk Time out in write sequence
O
command aborted
p
Time out to data shortage
R
IDE drive ready time out
S
unable to find track 0
T
(dummy)busy time out or so
Y
disk not present in write
Z
Not Ready in Command
z
other error
L
capacity error
W Disk Not Ready in command begins
X
disk not present in operation without write
Extra information for Retry detection and Drive SENSE DATA
A Retry mark will be displayed when retry was occurred.
Although DVPro T10 is designed to isolate a failed drive to avoid data corruption, it is necessary to check
drive for permanent failure or occasional failure by several retries on Write or Read.
A Retry mark can be seen on
“
RAID-x Normal
“
display if retries were performed.
While controller is at
normal operation, press MODE and SELECT button will allow you to check and clear the retry mark.
RAID-6
NORMAL
The retry mark is shown after
“NORMAL” case
G
-
Host write data transmission error
P
-
Host bus parity error before data out process ending
Q
-
Host bus parity error in middle of data out process
R
-
Host bus parity error on data in phase
I
-
Sequencer interrupt on Initiator error
:
-
Data out transmission error detected abortion of condition check
.
-
Data write recovered by retry
;
―
Read error occurred on parity generation read operation. Recovery was taken
※
When
「
S
」
or
「
Z
」
or
「
z
」
is appended, there
is high possibility that drive is failed.
Please contact technical support before
taking any action.
Summary of Contents for DVPro DVT12T3
Page 1: ...DVPro High Performance Storage System User Manual DVT12T3 Thunderbolt 3 User Manual Ver 1 0...
Page 2: ......
Page 5: ...DVT12T3 2...
Page 9: ...DVT12T3 6 Rear View Side View Disk 0 Disk 1 Disk 10...
Page 13: ...DVT12T3 10...
Page 44: ...BIOS AP Inc 41 2 8 3 IP Setup for MAC OS X Click System Preferences Click Network Icon...
Page 46: ...BIOS AP Inc 43...