8
a sealant heat-resistant cardboard between the fan and the smoke exhauster. It is
required to verify unhindered rotation of fan blades and then complete items
mentioned in Part 5 Installation. As well as replacement of sealant material shall be
carried out per recommendations of the manufacturing plant.
Technical maintenance shall be performed from time to time as dirt is
accumulated, once per two months is average normal period for the technical
maintenance.
6.2
Storage Instructions
The Smoke Exhauster shall be stored in closed heated premises in cardboard
or wooden boxes under the following conditions:
-
surrounding air temperature from 0 to 40°С;
-
relative air humidity of not more than 90% under temperature of 35°С. В There
should be no dust, fumes of acid and alkaline as well as aggressive gases in the
premises air.
Note: No special equipment or tools are required for technical maintenance
performance.
7
Failures and Troubleshooting Practice
#
Failure
Potential Reason
Troubleshooting Method
1
Smoke Exhauster has
a leakage problem
Poor treatment with sealant
material
1.
Carry out Item 6.1
Technical maintenance
procedure with thorough
treatment using the
sealant material.
2.
Tighten tightly the
clamp.
Size of the chimney flue
does not correspond with the
model of the smoke
exhauster used.
1.
Use the adapter for
your
smoke
exhauster
with
interim
diameter
that is suitable for
your model of the
smoke exhauster.
2