background image

 

 

 

a  sealant  heat-resistant  cardboard  between  the  fan  and  the  smoke  exhauster.  It  is 
required  to  verify  unhindered  rotation  of  fan  blades  and  then  complete  items 
mentioned in Part 5 Installation. As well as replacement of sealant material shall be 
carried out per recommendations of the manufacturing plant.    

Technical  maintenance  shall  be  performed  from  time  to  time  as  dirt  is 

accumulated,  once  per  two  months  is  average  normal  period  for  the  technical 
maintenance.     

6.2

 

Storage Instructions 

 

 

The Smoke Exhauster shall be stored in closed heated premises in cardboard 

or wooden boxes under the following conditions:   

-

 

surrounding air temperature from 0 to 40°С;   

-

 

relative air humidity of not more than 90% under temperature of 35°С.  В There 
should be no dust, fumes of acid and alkaline as well as aggressive gases in the 
premises air.  

 

 

Note: No special equipment or tools are required for technical maintenance 

performance. 

 

7

 

Failures and Troubleshooting Practice  

 

 

#  

Failure  

Potential Reason  

Troubleshooting Method  

1  

Smoke Exhauster has 
a leakage problem  

Poor treatment with sealant 
material  

1.

 

Carry out Item 6.1  
Technical maintenance 
procedure with thorough 
treatment using the 
sealant material.

 

 

2.

 

Tighten tightly the 
clamp. 

 

 

  

Size of the chimney flue 
does not correspond with the 
model of the smoke 
exhauster used.    

1.

 

Use  the  adapter  for 

your 

smoke 

exhauster 

with 

interim 

diameter 

that  is  suitable  for 
your  model  of  the 
smoke exhauster.    

2  

  

  

  

 

 

Summary of Contents for H-0220

Page 1: ...1 bioprom com ua Smoke Exhauster H 0220 For Chimney Flues with Diameter of 220 mm Operation Manual КБХ EX001 0220 00 00 РЭ ...

Page 2: ...ION CONCEPT 6 4 SAFETY MEASURES 6 5 INSTALLATION 6 6 TECHNICAL MAINTENANCE 7 6 1 Technical maintenance procedure 7 6 2 Storage instructions 8 7 FAILURES AND TROUBLESHOOTING PRACTICE 8 8 WARRANTY OBLIGATIONS 9 WARRANTY TICKET 10 RECORDS ON TECHNICAL MAINTENANCE PERFORMED 12 TICKET ON PUTTING INTO OPERATION 13 FOR NOTES 14 ...

Page 3: ...ment of the structure construction of Smoke Exhausters as well as their manufacturing technology this Operation Manual might contain some discrepancies in terms of description of the product unit and the unit itself and such discrepancies do not impact on the unit efficiency performance data and mounting dimensions 1 Product Description 1 1 Purpose Exhauster H 0220 Smoke Exhauster is intended for ...

Page 4: ...4 Picture 1 1 Fan R2e160 BG34 01 2 Smoke Exhauster H 0220 3 chimney flue 4 tie rods ...

Page 5: ...chnical Characteristics Basic parameters of Smoke Exhauster H 0220 are shown in Table 1 Table 1 Smoke Exhauster Performance Data Parameter Value Productivity rate 235 Power intake 57 Watt Weight 3 kg 5 kg Fan rpm adjustment Yes 10 100 _ weight with a fan ...

Page 6: ...exhauster clean up or maintenance make sure that the unit is de energized And in addition turn off the heating equipment to exclude flow of flue gases in the chimney flue 5 Installation The Smoke Exhauster is mounted into the chimney flue of the corresponding diameter A hollowing is done in the chimney flue in accordance with dimensions described in the Operation Manual or along the outline of ste...

Page 7: ... your boiler or stove to exclude the flow of flue gases in the chimney flue Remove the smoke exhauster from the chimney flue and remove the fan from the smoke exhauster Remove accumulated ash from the smoke exhauster unit using brush and vacuum cleaner Then it is required to clear the smoke exhauster mounting spot off any contamination dirt and sealant material The same procedure shall be carried ...

Page 8: ...ns surrounding air temperature from 0 to 40 С relative air humidity of not more than 90 under temperature of 35 С В There should be no dust fumes of acid and alkaline as well as aggressive gases in the premises air Note No special equipment or tools are required for technical maintenance performance 7 Failures and Troubleshooting Practice Failure Potential Reason Troubleshooting Method 1 Smoke Exh...

Page 9: ... to the seller of the smoke exhauster Warranty is valid if a user has not incorporated made any changes into the smoke exhauster configuration and construction Warranty does not cover smoke exhauster as well as defects occurred through user s fault due to violation of operation rules for the smoke exhauster willful damage repair or attempt to repair performed by an unauthorized individual power ou...

Page 10: ...me _____________________ _____________________ Tel _______________________ _____________________ City ______________________ _____________________ Street House _______________ _____________________ _______________________ For all issues relating to warranty and post warranty service please feel free to contact us at the address of 126 1 Plekhanovskaya Str Kharkov city 61037 Telephone of Service Ce...

Page 11: ...____________________ License ____________ Expert ________________ Repair Date __________________ stamp Record on warranty repair Defect description _______________________________________________________________ Reason for failure _______________________________________________________________ _______________________________________________________________________________ Repair work performed ___...

Page 12: ...12 RECORDS ON TECHNICAL MAINTENANCE PERFORMED Expert Service Center Signature Stamp Signature Stamp Notes ...

Page 13: ..._______________________________________________________________ __________________________________________________________________ ____________ Detailed info of the company that performed installation _____________________________________________________________________________ __________________________________________________________________ ______________________________________________________...

Page 14: ...14 FOR NOTES ...

Reviews: