Warranty Obligations

 

 

The  manufacturer  guarantees  failure-free  operation  of  Smoke  Exhauster  H-

0220 for the period of 12 months starting from the date of the first startup (putting 
into operation), but not longer than 24 months from the date of manufacture and on 
conditions that the unit is operated properly and undergoes technical maintenance 
in a timely manner.   

Warranty for the fan is granted for the period of 1 year.   

Warranty  is  valid  only  on  the  territory  of  the  country  where  the  smoke 

exhauster was sold to a user by the authorized representative of the manufacturer. 
For  all  issues  relating  to  warranty  a  user  shall  go  to  the  seller  of  the  smoke 
exhauster.   

 

 

Warranty is valid: 

  

-

 

if  a  user  has  not  incorporated  (made)  any  changes  into  the  smoke  exhauster 
configuration and construction;   

Warranty 

does not cover

 smoke exhauster, as well as defects occurred through: 

-

 

user’s fault due to violation of operation rules for the smoke exhauster; 

-

 

willful damage; 

-

 

repair (or attempt to repair) performed by an unauthorized individual; 

-

 

power outages; 

-

 

natural disasters (lightning strike, fire, flood, submergence, etc.). 

 

 

The  list  of  authorized  representatives  of  the  manufacturing  plant  can  be 

found on website of LTD «Bioprom Company Kharkov» bioprom.ua.   

The  manufacturer  reserves  the  right  to  incorporate  changes  into  the 

construction (smoke exhauster configuration) that do not worsen performance data.   

Company-manufacturer address: 

  

126/1, Plekhanovskaya Str., Kharkov city, 61037, Ukraine  
 
 
 
 
 
 
 
 
 
 

Summary of Contents for H-0220

Page 1: ...1 bioprom com ua Smoke Exhauster H 0220 For Chimney Flues with Diameter of 220 mm Operation Manual КБХ EX001 0220 00 00 РЭ ...

Page 2: ...ION CONCEPT 6 4 SAFETY MEASURES 6 5 INSTALLATION 6 6 TECHNICAL MAINTENANCE 7 6 1 Technical maintenance procedure 7 6 2 Storage instructions 8 7 FAILURES AND TROUBLESHOOTING PRACTICE 8 8 WARRANTY OBLIGATIONS 9 WARRANTY TICKET 10 RECORDS ON TECHNICAL MAINTENANCE PERFORMED 12 TICKET ON PUTTING INTO OPERATION 13 FOR NOTES 14 ...

Page 3: ...ment of the structure construction of Smoke Exhausters as well as their manufacturing technology this Operation Manual might contain some discrepancies in terms of description of the product unit and the unit itself and such discrepancies do not impact on the unit efficiency performance data and mounting dimensions 1 Product Description 1 1 Purpose Exhauster H 0220 Smoke Exhauster is intended for ...

Page 4: ...4 Picture 1 1 Fan R2e160 BG34 01 2 Smoke Exhauster H 0220 3 chimney flue 4 tie rods ...

Page 5: ...chnical Characteristics Basic parameters of Smoke Exhauster H 0220 are shown in Table 1 Table 1 Smoke Exhauster Performance Data Parameter Value Productivity rate 235 Power intake 57 Watt Weight 3 kg 5 kg Fan rpm adjustment Yes 10 100 _ weight with a fan ...

Page 6: ...exhauster clean up or maintenance make sure that the unit is de energized And in addition turn off the heating equipment to exclude flow of flue gases in the chimney flue 5 Installation The Smoke Exhauster is mounted into the chimney flue of the corresponding diameter A hollowing is done in the chimney flue in accordance with dimensions described in the Operation Manual or along the outline of ste...

Page 7: ... your boiler or stove to exclude the flow of flue gases in the chimney flue Remove the smoke exhauster from the chimney flue and remove the fan from the smoke exhauster Remove accumulated ash from the smoke exhauster unit using brush and vacuum cleaner Then it is required to clear the smoke exhauster mounting spot off any contamination dirt and sealant material The same procedure shall be carried ...

Page 8: ...ns surrounding air temperature from 0 to 40 С relative air humidity of not more than 90 under temperature of 35 С В There should be no dust fumes of acid and alkaline as well as aggressive gases in the premises air Note No special equipment or tools are required for technical maintenance performance 7 Failures and Troubleshooting Practice Failure Potential Reason Troubleshooting Method 1 Smoke Exh...

Page 9: ... to the seller of the smoke exhauster Warranty is valid if a user has not incorporated made any changes into the smoke exhauster configuration and construction Warranty does not cover smoke exhauster as well as defects occurred through user s fault due to violation of operation rules for the smoke exhauster willful damage repair or attempt to repair performed by an unauthorized individual power ou...

Page 10: ...me _____________________ _____________________ Tel _______________________ _____________________ City ______________________ _____________________ Street House _______________ _____________________ _______________________ For all issues relating to warranty and post warranty service please feel free to contact us at the address of 126 1 Plekhanovskaya Str Kharkov city 61037 Telephone of Service Ce...

Page 11: ...____________________ License ____________ Expert ________________ Repair Date __________________ stamp Record on warranty repair Defect description _______________________________________________________________ Reason for failure _______________________________________________________________ _______________________________________________________________________________ Repair work performed ___...

Page 12: ...12 RECORDS ON TECHNICAL MAINTENANCE PERFORMED Expert Service Center Signature Stamp Signature Stamp Notes ...

Page 13: ..._______________________________________________________________ __________________________________________________________________ ____________ Detailed info of the company that performed installation _____________________________________________________________________________ __________________________________________________________________ ______________________________________________________...

Page 14: ...14 FOR NOTES ...

Reviews: