BioNano Genomics Saphyr 60325 System Safety Manual Download Page 3

 

 

30253 Rev A, Saphyr System Safety Guide for Saphyr P/N 60325 

Page 3 of 9 

Legal Notice   

 

For Research Use Only. Not for use in diagnostic procedures. 

This material is protected by United States Copyright Law and International Treaties. Unauthorized use of this 
material is prohibited. No part of the publication may be copied, reproduced, distributed, translated, reverse-
engineered or transmitted in any form or by any media, or by any means, whether now known or unknown, 
without the express prior permission in writing from Bionano Genomics. Copying, under the law, includes 
translating into another language or format. The technical data contained herein is intended for ultimate 
destinations permitted by U.S. law. Diversion contrary to U. S. law prohibited. This publication represents the 
latest information available at the time of release. Due to continuous efforts to improve the product, technical 
changes may occur that are not reflected in this document. Bionano Genomics reserves the right to make 
changes in specifications and other information contained in this publication at any time and without prior notice. 
Please contact Bionano Genomics Customer Support for the latest information. 

 

BIONANO GENOMICS DISCLAIMS ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED 
OR IMPLIED, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE. TO THE FULLEST EXTENT ALLOWED BY LAW, IN NO EVENT SHALL BIONANO 
GENOMICS BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR UNDER ANY STATUTE OR ON 
ANY OTHER BASIS FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL 
DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED 
TO THE USE THEREOF, WHETHER OR NOT FORESEEABLE AND WHETHER OR NOT BIONANO 
GENOMICS IS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 

 

Patents 

Products of Bionano Genomics may be covered by one or more U.S. or foreign patents. 

 

Trademarks 

The Bionano Genomics logo and names of Bionano Genomics products or services are registered trademarks or 
trademarks owned by Bionano Genomics in the United States and certain other countries. 

 

Bionano Genomics®, Saphyr®, Saphyr Chip®, and Bionano Access® are trademarks of Bionano Genomics, Inc. 
All other trademarks are the sole property of their respective owners. 

 

No license to use any trademarks of Bionano Genomics is given or implied. Users are not permitted to use these 
trademarks without the prior written consent of Bionano Genomics. The use of these trademarks or any other 
materials, except as permitted herein, is expressly prohibited and may be in violation of federal or other applicable 
laws. 

 

© Copyright 2019 Bionano Genomics, Inc. All rights reserved. 
 

 

Summary of Contents for Saphyr 60325

Page 1: ...r Research Use Only Not for use in diagnostic procedures Copyright 2019 Bionano Genomics Inc All Rights Reserved Saphyr System Safety Guide for Saphyr P N 60325 Document Number 30253 Document Revision...

Page 2: ...ety Guide 5 Important 5 Safety Warnings 5 Laser Safety Warnings 6 Preventing Radiation Exposure 6 Safety Labeling 6 Sound Level Safety Warnings 7 LED Exposure Warning 7 Electrical Safety Warnings 7 El...

Page 3: ...RESPECT TO THIS DOCUMENT EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE FULLEST EXTENT ALLOWED BY LAW IN NO EVENT SHALL BIONANO G...

Page 4: ...30253 Rev A Saphyr System Safety Guide for Saphyr P N 60325 Page 4 of 9 Revision History Revision Notes A Initial Release...

Page 5: ...ormation and warnings that must be followed by the customer for safe operation and for keeping the product in a safe condition Before use of the instrument please review all safety instructions to avo...

Page 6: ...uct is hazardous if the eye is directly exposed to the laser However the diffuse reflections are not harmful Protective eye wear is required when a person is viewing a class 3B laser beam All Class 4...

Page 7: ...ards Only Bionano Field Service Engineers or Bionano certified personnel are qualified to replace the internal fuses The power entry module includes two input fuses on the high voltage input lines Und...

Page 8: ...103 kg 227 lb Environmental Considerations This instrument is designed for indoor use only Element Specification Temperature Maintain a lab temperature of 19 C 66 F to 25 C 77 F Humidity Maintain a n...

Page 9: ...requently asked questions and other related documents from the Support website or by request through e mail and telephone Type Contact Email support bionanogenomics com Phone Hours of Operation Monday...

Reviews: