Parameter
Description
Allowed value
Code
Test code which appears in the test grid.
Can be composed of a maximum
of 3 characters.
Method Description
Full test name.
Text.
Tray
Number of the reagent tray on which the
reagent will be located.
Up to 4 reagent trays can be
defined.
Units
Unit use to express the results for this
parameter.
Text
Linearity limit
This is the results value above which
chemical response is not linear and therefore
there is not a linear correspondence between
the
increase
of
absorbance
and
concentration. For higher results, the tests
shall be repeated with dilution
Number
Min. Reag. Blank (O.D)
This is the value of absorbance of the
reagent blank (only reagent) under which the
reagent cannot be considered as working
correctly.
OD value.
Max Reag. Blank (O.D)
This is the value of absorbance of the
reagent blank (only reagent) over which the
reagent cannot be considered as working
correctly.
OD Value
Decimal Positions
Here, the operator can define how many
decimal figures will be displayed for the result
and therefore will be used for calculation.
Note that the upper five rounding method is
applied. Therefore for a result of 1.365, for 2
digits, the result shown will be 1.37.
0-1-2-3-4
Mix
Here, the operator can select the extra
mixing
mode.
R1
and
sample
are
automatically mixed, and can be mixed once
more if “1” or “3” are selected.
The reagent mix can be mixed again after
addition of R2 if “2” or “3” are selected.
For monoreagent reaction, we advice “0”.
For bi-reagent reactions, we advice “2”.
0 : No extra mix
1 : extra mix after addition of R1
2 : extra mix after addition of R2
3 : extra mix after addition of R1
and R2.
STD lot
The lot number of standard used or of the
multi-parametric calibrator.
Text
Reagent Lot
Lot Number of the reagent.
Text
Dilution
This is the rate to be used in case of test
repetition with dilution.
1:2 : Sample volume divided by 2
1:5 => 1:100 : post-dilution ratio.
The sample will be automatically
diluted in a reading cuvette.
Reagent Code
Reference of the reagent
Text
Summary of Contents for KENZA 240 TX
Page 5: ...5 1General Information...
Page 10: ...10 2Installation...
Page 14: ...14 3Preliminary operations...
Page 17: ...17 4Methods programming...
Page 30: ...30 5Calibrations and controls...
Page 37: ...37 6Prepare the run...
Page 47: ...47 7During the run...
Page 51: ...51 8After the run...