background image

Table of Contents

 

Warranty

The Desert Chamber Pro warranty is for one year from receipt of purchase and covers all parts and labor when performed solely by 
Biocare Medical. Warranty is invalidated if equipment is abused, damaged, or improperly maintained by customer. Warranty is not 
transferable to any other party should the equipment be resold or transferred by the customer to another party. To the extent permitted 
by law, Biocare Medical disclaims any liability for any incidental or consequential damages related to this equipment or for any warranty 
related services it performs.

Not for use with flammable solvents or gases

Overview ................................................................................................................................................................................ 1

Specifications ........................................................................................................................................................................ 2

Unit Specifications ................................................................................................................................................................. 2

Unit Construction ................................................................................................................................................................... 2

Contents ................................................................................................................................................................................ 2

Assembling the Oven .............................................................................................................................................................. 3

Electrical Precautions ............................................................................................................................................................. 3

Maintenance .......................................................................................................................................................................... 3

Slide Drying Protocol For Immunohistochemistry ....................................................................................................................... 4

Slide Loading Guidelines ......................................................................................................................................................... 4

Manual Operation Instructions ................................................................................................................................................. 5

Preset Program Descriptions .................................................................................................................................................... 6

Preset Program Operation Instructions ...................................................................................................................................... 7

Checking the Sequence ........................................................................................................................................................... 8

Changing Between Preset Programs .......................................................................................................................................... 8

Appendix 1: Program Function Map .......................................................................................................................................... 9

Appendix 2: Function Menu ................................................................................................................................................... 11

Quick Operation Guide .......................................................................................................................................................... 12

Summary of Contents for Desert Chamber Pro

Page 1: ...www biocare net Desert Chamber Pro Manual Turbo Fan Slide Drying Oven DRY2008INT ...

Page 2: ...Biocare Medical Technical Support 800 799 9499 Option 3 Customer Service 800 799 9499 Fax 925 603 8080 Corporate Office 60 Berry Drive Pacheco CA 94553 www biocare net ...

Page 3: ...ms any liability for any incidental or consequential damages related to this equipment or for any warranty related services it performs Not for use with flammable solvents or gases Overview 1 Specifications 2 Unit Specifications 2 Unit Construction 2 Contents 2 Assembling the Oven 3 Electrical Precautions 3 Maintenance 3 Slide Drying Protocol For Immunohistochemistry 4 Slide Loading Guidelines 4 M...

Page 4: ...mperature process controller makes this oven superior to other conventional drying ovens This controller will autocalibrate for the amount of mass and volume placed inside the oven keeping the inside temperature constant and accurate The Desert Chamber Pro can be programmed with variable segments times temperatures and alarms On Off Switch Temperature Up Temperature Down Main Control Button Contro...

Page 5: ...re 10 C 35 C 50 F 95 F 80 maximum relative humidity Storage Temperature 10 C 70 C 14 F 158 F 70 maximum relative humidity Approvals Underwriter s Laboratory Listed Laboratory Equipment C UL United States Canadian E212550 115 VAC models only Compliance UL Standard 61010 1 IEC 61010 1 2nd Edition Unit Construction Exterior Powder coated steel Insulation Fiberglass Thermo control PID microprocessor I...

Page 6: ...erate the instrument with a damaged cord or plug Do not let the cord hang over the edge of a table or counter or touch hot surfaces Important Note The oven temperature has been calibrated at the factory and should not be adjusted by the end user If any problems arise with the oven call Biocare Medical for technical service at 800 799 9499 Maintenance The Desert Chamber Pro oven is designed to be v...

Page 7: ...nd tap on the counter to remove residual water Position slide rack in oven Close oven door Dry slides using one of the Preset Programs All the water should be evaporated from beneath the tissue section and the glass slide and the paraffin should be melted prior to deparaffinization and HIER Note the times may vary according to the number of slides placed in the oven Technical Notes Under fixed tis...

Page 8: ...h and release the up arrow twice and finally push the asterisk button and down arrow simultaneously 2 Do not end a programmed run prematurely by turning off the using the On Off button Make sure the LED display shows the temperatures before stopping a manual run using the On Off button Run Off will be displayed until the LED displays the temperatures This may take several minutes 3 To turn off the...

Page 9: ...P 3 Program 3 Bulk Program Segment 1 45 C for 30 minutes Segment 2 70 C for 30 minutes Level P 4 Program 4 Overnight Program Segment 1 37 C for 60 minutes Segment 2 60 C for 60 minutes Level P 5 Program 5 Delayed Program Segment 1 25 C for 720 minutes Segment 2 37 C for 60 minutes Segment 3 60 C for 60 minutes Note All programs can be customized to user defined specification Temperatures over 60 7...

Page 10: ...will start immediately however it may take several minutes to display 8 At the start of a run the display will read SPr in green with the target temperature in red When the set temperature is reached the display will read SoAK in green alternating with the actual temperature Stopping a Program Run Off 1 To stop a program similar steps to starting a program are repeated 2 Press the up and down arro...

Page 11: ...tton and immediately release The screen will display Program 1 5 3 Press the up arrow button once and immediately release The screen will display Run On 4 Press and hold the asterisk button and press the down arrow once immediately release The screen will read Run Off 5 Press and hold the up and down arrow buttons until the screen displays the temperature 6 Press and hold the up and down arrows bu...

Page 12: ...ogram press once Add new programs at top of existing menu Select the required program number Default 1 Memory used Select program mode of operation Default off Powerfailurerecovery position Default reset Select the starting point of program after power up Default PV Ramp rate time units adjustment Default hour Options start program at main SP or process variable Options hours minutes 3 secs 3 secs...

Page 13: ... used after selecting the segment type to confirm it s selection Adjusts ramp rate Default 100 Soak time in minutes or continue Default 10 Define the program number called Default none Set Numbers of re cycles 1 to 999 unless full Or continuous Default 1 Returns to SEG Target set point adjustable over the unit s range Default Current main SP Holdback this functiononly appearsforrampoperational onc...

Page 14: ...band gain hyst 0 1 deg to 100 sensor f s 10 C 18 F Integral time reset Off 0 1 to 60 min 5 min Derivativetime rate Off 1 to 200 sec 25 sec Derivative approach 0 5 to 5 0 x bAnd 1 5 Cycle time or on off On off 0 1 to 81 sec 20 sec Offset manual reset 0 to 50 x bAnd In t off Setpoint lock SP1 Off on Adjust SP2 setpoint sensor full scale or full scale SP2 prop band Gain Hyst 0 1 deg to 100 sensor f s...

Page 15: ...se The screen will read Run on Turning Off a Program 1 Hold the up and down arrows simultaneously for five seconds Level P will be displayed 2 Push the up arrow and immediately release Program 1 will be displayed Select the desired program 3 Push the up arrow once and release Run On will be displayed 4 Push the asterisk button and push the down arrow and immediately release The screen will read Ru...

Page 16: ...800 799 9499 60 Berry Drive Pacheco CA 94553 www biocare net 904 009 071817 ...

Reviews: