11
Cal
l su
b-p
rog
ram
nu
mb
er
nonE
; 1 to number
of programs
Soak time interval
Cont
; 0.1 to 1400
(10) min
Program re-cycle count
Cont
; 1 to 999
Derivative sensitivity
0.1
to
1.0
x d
Er.t
(
0.5
)
Display averaging
dir
; 1 to 32 (
6
)
Disable -AL- alarm
display
; on
Dis
abl
e p
rog
ram
au
to-
exi
t
Auto
; St
AY
Security lock
nonE
; LEV 3; LEV 2; ALL
Cha
nge
pro
gra
m e
ntr
y p
oin
t
Off
; on
USER-PROTECTED SETTINGS
SP2 output device
non
e
; SS
d; r
ly; (
rea
d o
nly
)
Sensor burn-out
uP.
SC
; dn
.SC
; 1u
.2d
; 1d
.2u
Zero adjustment
0.0
to 25% sensor
full scale
Set Monitor
Off
; on
Read Monitor
VAr; hi; lo deg Read
Tune Data
CtA; Ctb; Ct1; Ct2; Ct3; Ct4;
oS1; uS; oS2
Software version
Consult unit
RESET
nonE
; ALL
SP1 output device
no
ne
; rly;
SS
d; A
nLG
Reverse outputs
1r.2d
; 1d.2d; 1
r.2r; 1d.2r
Reverse O/P LEDs
1n.2n
; 1i.2n; 1n.2i; 1i.2i
Span adjustment
0.0
to 25% sensor
full scale
CONFIGURE OUTPUT
SAFETY SETTINGS
CALIBRATION
PERFORMANCE DATA
Read SP1 output %
0 t
o 1
00%
rea
d o
nly
SP1 manual output %
0
to1
00%
pro
por
tion
al
mode only
Limit SP1 output %
100
to 0%
Limit SP2 output %
100
to 0%
Main SP2 mode
nonE
; dV
.hi; d
V.Lo; bAnd;
FS.hi; FS.Lo; Cool; EoP
Second SP2 mode
non
E
; Lt
CH
; ho
ld;
Lt.h
o;
nLin
Display resolution
1
or 0.1 degree
Set scale maximum
0.0
Se
nso
r m
ax
to s
ens
or
full scale
Set scale minimum
0.0
Sen
sor
mi
n to
sen
sor
full scale
Select input sensor
nonE
Select display units
nonE
;
°
C;
°
F; bAr;
PSi; Ph; rH; SEt
\\
MANUAL ADJUSTMENTS
SP2 MODES
CONFIGURE INPUT
RANGING
SP1 SETTINGS
SP2 SETTINGS
Autotune or Park
Off
; on; ParK; At.SP
SP1 Prop band (gain)/
hyst 0.1 deg to 100%
sensor f/s (
10
°
C/18
°
F
)
Integral time (reset)
Off; 0.1 to 60 min
(
5 min
)
De
riva
tive
tim
e (r
ate
)
Off
; 1
to 2
00
sec
(
25 sec
)
Derivative approach
0.5 to 5.0 x bAnd
(
1.5
)
Cycle time or on/off
On.off; 0.1 to 81 sec
(
20 sec
)
Offset (manual reset)
0 to 50% x bAnd
(
In.t = off
)
Setpoint lock (SP1)
Off
; on
Adjust SP2 setpoint
+/
– se
nso
r fu
ll sc
ale
or
full scale
SP2 prop band/Gain/
Hyst 0.1 deg to 100%
sensor f/s (
2
°
C/3.6
°
F
)
SP2 Cycle on/off
On.off
; 0.1 to 81 sec
Program number
1
to 31
Run program
oFF
; on; hoLd; dEL
inS; CoP
Y; PStE
Power failure
recovery mode
rSEt
; Cont; hoLd
Program start value
PV
; SP
Setpoint ramp time units
hour
; 60s
Holdback value
oFF
; 0.1 to 150
Event output (SP2A or SP3A)
non
E
; 2d
; 2E
; 3d
; 3E
; 2d
.3d
;
2E.3d; 2d.3E; 2E.3E
PROGRAMMER SETTINGS
S
egment number
1
to 126 max.Define segment type
SPr
; So
AK
; St
EP;
Lo
oP;
C
all;
Eo
P; d
EL;
inS
Setpoint ramp rate
1 to 9990 (
100
)
units/time
Adjust target setpoint
+/
– se
nso
r fu
ll sc
ale
or
full scale
Instrument address
0
to 255
Baud rate
1200; 2400; 4800
9600
; 19k2
Data format
18n1
; 18E1; 1801
TxRx activity
Off
; on
COMMS SETTINGS
High scale
1000
-1999 to 9999
Low scale
0
-1999 to 9999
Input high
50.0
0.1 to 50.0
Input low
10.0
0.0 to 49.9
Decimel
0000
000.0 or 00.00
Burnout SP3 -
uPSC
dhSC
R
everse O/P3
3D
3r
SP3 SAFETY SETTINGS
Main mode
nonE
d
v.hi; dVLo; bAnd; Fshi;
FSLo; EoP
Second mode
nonE
LtCh; hoLd; Lt.ho
Set SP3
0
0 to 2500
Hysteresis SP3
20
1–100% sensor
full scale
SP3 ADJUSTMENTS
SP3 MODES
LINEAR SCALING AND INPUT SETTINGS
INITIAL
SET-UP
ENTRY
PROGRAM ENTRY (DEFAULT)
Level C only visible
when COMMS
Option fitted
KEY
OR
TOGETHER TO CHANGE LEVELS OR OPTIONS
KEY
OR
TO VIEW FUNCTIONS
Appendix 2: Function Menu