MESSAGE
DISPLAYED
/ FAULT
DETECTED
IMMEDIATE AUTOMATIC
ACTION
CAUSE
CHECKS AND REMEDIES
OPTION TO
DEACTIVATE
VIA THE MENU
«
Parameters -
Alarms
»
Stopping
production
Stopping pH
regulation
Alarm
Com.
Failure
Yes
No
Loss of communication
between the control
board and the power
board of the
electronics unit.
Contact a professional.
No
Alarm
pH
Calibration
No
Yes
pH probe incorrectly
calibrated.
Carry out a calibration of the pH
probe.
Yes
Alarm
No water
Yes
Yes
Insufficient amount of
water in the filtration
circuit.
Check that the filtration pump is
running correctly.
Yes
Alarm
Low Salt
Yes
No
Salt level less than
2.5g/L (or 1.5g/L if Low
Salt equipment).
•
Check the salt levels in the pool
using a recent testing kit.
•
Top up with salt if necessary, so
as to obtain a salt level of 5 kg/m
3
(or 2.5 kg/m
3
for Low Salt
equipment).
Yes
Insufficient amount of
water in the filtration
circuit.
•
Check that the pipe at the level of
the salt sensor is completely filled
with water.
•
If necessary, top up the water in
the pool.
Alarm
Change UV
Lamp
No
No
UV lamp at end of life
•
Lamp to be replaced within 500
hours of the UV lamp operation
No
Alarm
UV Lampe pb
No
No
The lamp is bad
connected
Check good connection of the lamp
No
The lamp cable is
damaged or
disconnected
Check state of the lamp cable and
its connections
The ballast is in safety
(micro cut or fast on /
off)
Switch off the electrical box for a
few seconds then switch it on again.
The electronic ballast
returns a defect
•
Check the state of the lamp and
replace it if needed
•
Check the state of the ballast and
replace it if needed
G.9.3. Important precautions regarding the peristaltic pump
When one of the 2 messages below is displayed, the peristaltic pump is running.
Manual Injection
XX:XX
→ Real-time timer countdown
or
pH Injection
In Progress
In this case, never remove the front panel of the electronics unit.
→
If case of doubt about the correct functioning of the peristaltic pump :
1)
Switch off the electronics unit.
2)
Remove the front cover of the electronics unit.
3)
Remove the flexible hose inside the peristaltic pump.
4)
Carry out a manual vacuum injection.