F.10. Instructions for electrical connections
IMPORTANT :
•
Connections must be made by a qualified technician.
•
A residual current device (RCD) not exceeding 30mA must be present and a fuse
or a thermal breaker should be installed on the device power supply.
•
The supply voltage must be the same as that described on the label affixed to the side
of the unit.
•
The
O’Clear ultraviolet equipment must be used for filtration and thus operate with this
device => the power cable must be wired to the contactor coil of the pump (timer) in
220-240V (Caution to 380V!) the main electrical cabinet (See wiring diagrams below)
•
Before making connections, turn off the power supply.
•
A disconnection means must be provided on the power supply of the device to allow a
complete power cut according to the installation rules. This should be marked in order
to be quickly identified
•
A disconnection means shall be provided in the fixed piping according to the installation
rules
The
O’Clear device has been wired for a connection to the ground !
F.10.1. Electrical connections on the electrical cabinet O Clear
Cabinet connections :
T°
: Connection for temperature sensor
Flow
: Connection for flow swich
or
empty container sensor.
com
: Modbus connection (not used)
Ext
: Connection for a flap position switch,
or
an external control,
pH
: Connection of the pH probe