GENERAL INFORMATION:
This operating manual describes all possible options,
Some of them aren’t available on your device according to your reactor type.
Definition of the 3 letters on the first display
R
means that the reactor is switched on and operating.
F
means that the water is flowing and that the flow is adequate in relation to the
setting that you made on the flowmeter.
C
means that the automatic cleaning function is activated.
Note: for the reactors which don't have a flowmeter, the letter “F” stays always on the display.
●
The screen is backlit: Just pressing on a key switches the back lighting on for one minute.
●
Activation/deactivation of automatic cleaning: Pressing simultaneously on buttons A and B activates or
deactivates the automatic cleaning.
●
Caution: if the cleaning is deactivated when the hydraulic cylinder is operating, the cleaning carriage may stop
in the middle of the reactor and block some of the UV rays.
ALERT MESSAGES:
The screen flashes when there is an alert message.
The alert messages are always shown on the secondary display and are independent of what is displayed on the
main display unit.
Display
Meaning of the alert
Solutions
This message appears when the
temperature of the cabinet exceeds 60°C.
The reactor is stopped automatically.
Check that the cabinet vents are not blocked.
Check that the fans are working properly.
This message appears when the
temperature of the reactor exceeds
44.5°C.
The lamps are stopped automatically.
Check that enough water is flowing through the
installation.
If there is a flowmeter, check that is correctly
calibrated.
This message appears when one or
several lamps are faulty.
The numbers show which of the lamps
are faulty.
Diagnose the cause of the breakdown.
This message appears when the
hydraulic cylinder on the automatic
cleaning is blocked.
Diagnose the cause of the breakdown.
These 4 alert messages can be cleared by pressing on the key "OK".
It is preferable to carry out a maintenance operation before clearing the fault.
This message appears when the intensity
of the UVC radiation falls below the
pre-alarm threshold.
Check that the quartz sleeves are clean.
Check that the UV sensor is clean.
N.B.: when the lamps have been operating for a certain number of hours, this message appears naturally (normal wear of the lamps)
This message appears when intensity of
the UVC radiation falls below the main-
alarm threshold.
Check that the quartz sleeves are clean.
Check that the UV sensor is clean.
Chang the UV lamps.
This message appears when the lamps have been stopped (brought about by a safety
device). The lamps will not be relit until after a time delay of 30 minutes. This time delay is
to protect the lamps.
These 3 messages cannot be cleared unless the problem has been resolved.