6
Remove carefully the quartz sleeve :
Insert a thumb or finger in the sleeve and withdraw it gently until the seal comes free from its
housing, while remaining well aligned with the axis.
7
Take hold of the quartz sleeve and extract it fully, making sure that you keep it
ABSOLUTELY
well aligned with the axis.
8
Clean the quartz sleeve
with acid or white vinegar or replace it if necessary.
9
Make sure the tubular sleeve is in place at the bottom of the quartz sleeve
While remaining well aligned with the axis, introduce the clean quartz sleeve into the reactor
to its guide at the bottom of the reactor.
With your finger inside the sleeve position the quartz into the spring seat at the bottom of the
reactor. The quartz should be slightly out.
If the quartz is correctly positioned in the seat, flexibility can be felt by pressing on it (spring
effect).
10
Replace the o-ring :
(Mount a new seal at each lamp replacement)
•
Apply water and soap on the seal,
•
Position it around the quartz sleeve,
•
Fully push it into its location with the finger or the flat washer (do not use tools).
11
Replace the flat washer.
Screw back normally the stainless steel nut with hand