A.
TECHNICAL CHARACTERISTICS
BIOSUN RANGE
UNIT
BIOSUN 340
FUNCTIONAL CHARACTERISTICS
Flow rate
l/h
500
Number of hours of production per day
h
4
Volume produced per day
m3
2
Standalone operating time
day
3
Draw-off
-
Standalone operating time
Volume meter
-
Draw-off
UV reactor ON/OFF switch
-
Yes, with integrated LED
WATER SUPPLY
Tank volume
l
21
tank materials
-
304L stainless steel
Supply type
-
Manual or gravity filling < 1 bar
Max. pressure
bar
1
Pump
Vdc
24 (with a built-in pressure switch)
FILTERING
Filtering media
-
Zeolite
filter volume
l
7
filtering threshold
µm
<10
backwashing
-
With manual handle
cartridge size (optional)
inch
10
Filter cartridge type (optional)
-
10µm, activated carbon
UV REACTOR
UV lamp power
W
14
UV power delivered
W
4.6
UV operating light
-
Yes
Dose delivered
mJ/cm²
40
Ballast
-
Electronic (24VDC)
Supply voltage
Vdc
24
Average life expectancy for one stop/start per day
year
1
FRAME
Dimensions
mm
1400 x 600 x 400
Material
-
Fibe polyester complex: special for outdoor
use
PHOTOVOLTAIC POWER SUPPLY
Panel size (unit)
mm
1200 x 600
Number of solar panels
-
4
Panel power
W
85
Panel voltage
V
12
Panel attachment
-
Remote support (roof, floor, etc.)
Number of batteries
-
2
Battery type
-
70Ah(C100), 60Ah(C20), 12V
OPTION WITHOUT PHOTOVOLTAÏC PANELS
Recommended spare parts list to be provided by the customer
Solar panel
-
4
Number of batteries
-
2
Battery type
-
70Ah(C100), 60Ah(C20), 12V
Controller
-
According to panel model specified by the customer
Converter
-
24Vdc 100W