background image

8

F

AUCET

I

NSTALLATION

C

ONT

.

1.

Select faucet location.

• Make sure the faucet is far enough away so not to interfere with the regular faucet or any other attachments.
• If mounting faucet on the countertop, make certain the spout of the faucet will reach over the sink.
• Check underneath the sink/countertop for any obstructions and for tool clearances required for mounting the faucet.
• Make certain the faucet will fit flat against the sink/countertop, so 1-7/8 inch rubber washer will seal against 

chrome base plate and sink/countertop.

2.

Mark the center of the faucet location.

CAUTION:

To avoid possibly damaging sink and/or countertop, consult a qualified plumber or installer, 

special tools may be required for drilling porcelain, stainless steel, tile, etc.

3.

Using appropriate tools for particular sink or countertop construction, make a 1/2 inch diameter mounting hole.

4.

Install the 1-1/4 inch rubber washer onto the faucet, followed by the chrome base plate, and finally the 1-7/8 inch 
rubber washer. These parts must be installed onto the faucet before mounting the faucet to the sink or countertop.

5.

Install faucet into the mounting hole. From under the sink install the 1-3/4 inch washer, the locking washer and 
thread the 9/16 inch nut onto the faucet. Align the faucet to desired position, and firmly tighten the nut.

6.

Install John Guest

Tubing Connector on to the inlet of the faucet. Insert 1/4 inch OD tubing into the end of 

tubing connector. See “

Tubing Installation

”.

S

YSTEM

I

NSTALLATION

1.

Once a suitable location, for the system, has been chosen, mark the location of the mounting screws, using the 
holes on the mounting bracket as a template.

2.

Using appropriate fasteners, for the type wall chosen, mount the system through the holes of the mounting bracket.

3.

Tubing Connections:
a. Run the tubing, connected to the saddle valve, to the inlet fitting of the sediment filter. 
b. Run the precut 24" tubing from the outlet of the carbon filter, to the inlet of the 

Bio-Logic

®

water purifier.

c. Run the tubing from the faucet to the outlet of the 

Bio-Logic

®

water purifier. Measure, cut tubing. The tubing 

must be cut square, free of burrs and sharp edges. Leave enough slack in the tubing so the system can be easily 
removed, if necessary.

4.

Turn on the faucet, supplied by the 

Pure Water Pack

system. NOTE: Lifting the handle, of the faucet, will 

lock the faucet in the “ON” position, while holding the handle down the faucet is “ON”, the faucet well shut off 
when the handle is released. Slowly open the saddle valve, by turning the “T” handle counter-clockwise until fully 
open, and allow the system to fill with water.

5.

Once water begins to flow from the faucet, allow water to run for several minutes until it is clear with no air 
bubbles. Turn off the faucet and check the system for leaks. If leaks occur see “

Troubleshooting

” section. If no 

leaks occur, proceed to install the ultraviolet lamp.

6.

Unpack the lamp and ballast. While holding lamp end, carefully push lamp socket on. Carefully slide lamp straight
into the quartz sleeve, without angling. Push the end cap on, over the static gland nut. For 120v or 220-240v 
operation, attach the ground connector to the grounding tab of the chamber.

CAUTION:

Lamp and quartz sleeve are easily damaged. Exercise care when handling.

7.

For 120v operation

, plug ballast into an approved Ground Fault Circuit Interrupt (GFCI) receptacle. Where a 

2-prong or unprotected 3-prong receptacle is encountered, it must be replaced by a properly grounded Ground 
Fault Circuit Interrupt (GFCI) receptacle.  Installation must be in accordance with the National Electrical Code 
and any local codes and ordinances by a qualified Electrician.

For 12v DC operation

;

• The ballast must be wired to an adequate 12v DC source with appropriate gauge wire for the voltage and current. It 

is recommended that the ballast have a dedicated run to the 12v source, and protected by either a fuse or circuit breaker.

• Always disconnect the battery(s), or other 12v source, before installation or performing any maintenance.
• The ballast is supplied with a 6-foot, 2 wire, power cord and 5-foot lamp cord, the ballast must be located so the 

lamp is easily removed and does put any tension on the lamp, which could cause damage to the lamp and/or 
quartz sleeve. All installed wiring should be protected from heat, wear points (abrading) or mechanical stress. 
Secure ballast using the mounting tabs located on the ballast body.

• Wire ballast power cord as follows;

Brown wire - Positive (+) to protected (fuse or circuit breaker) 12v DC source.
Blue wire - Negative (-) to suitable chassis ground.

• If there are any questions or concerns regarding the installation and/or wiring of the 12v system, consult a qualified installer.

8.

It is recommended, when the carbon filter is new, to flush out the system thoroughly prior to use. Turn on the 

!

Summary of Contents for BIO-1.5

Page 1: ...auge NY 11788 USA 631 273 0500 Fax 631 273 0771 e mail info ultraviolet com Extensive Product Information Available at www ultraviolet com Document No 98 1124B6 Revised December 2010 2002 2010 Atlanti...

Page 2: ...instructions generally describe the installation operation and maintenance of the Bio Logic Pure Water Pack Questions that are not specifically answered by these instructions should be directed to th...

Page 3: ...RUCTIONS WARNING To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL safety instructions 2 Do not use this system for other than its inten...

Page 4: ...flow through the disinfection chamber exposing it to the germicidal lamp Exposure time is related to the flow rate the higher the flow rate the lower the exposure time or the lower the flow rate the h...

Page 5: ...thod of replacing the quartz sleeve in your water purifier The Bio Logic Pure Water Pack is shipped with the lamp packed separately Keep the lamp aside for installation once the Pure Water Pack has be...

Page 6: ...t be connected to the cold water line only 4 The system should be located as close to the faucet as possible 5 CAUTION As with any water handling device the water purifier should be located in an area...

Page 7: ...turning the T handle clockwise until it is firmly seated The valve is CLOSED in this position 4 Open the cold water supply valve or main valve check for any signs of leaks around valve connection 5 In...

Page 8: ...Lifting the handle of the faucet will lock the faucet in the ON position while holding the handle down the faucet is ON the faucet well shut off when the handle is released Slowly open the saddle valv...

Page 9: ...se of this system For any questions concerns or technical assistance regarding this system or any of our other products contact our application specialists Contact options can be found in the User Ass...

Page 10: ...er purifier 2 Shut off water supply to the system by closing the supply valve Open the system faucet and allow the system to drain 3 Release the pressure in the filter housing by pressing the red pres...

Page 11: ...to water purifier until lamp and both easy off end caps have been properly reinstalled 7 Reattach the ground connector to the grounding tab of the chamber and restore power to the system DISPOSAL OF M...

Page 12: ...ochloric acid NOTE Follow all manufacturer s instructions and precautions when handling chemicals 8 Reassemble in reverse order Make sure the quartz sleeve protrudes an equal distance past each thread...

Page 13: ...the head clamp around the flared ends of the head and chamber Install the 1 4 nut and tighten using a 7 16 wrench until approximately 7 8 to 1 of the bolt protrudes past the nut 11 Carefully insert qu...

Page 14: ...ir bubbles Water contains black particles New carbon filter cartridges Open system faucet allow water to run purging the contain activated carbon carbon particles from the cartridge until water is cle...

Page 15: ...John GuestTM Connector Number of Lamps 1 Lamp Model No 05 1366 R Quartz Sleeve Yes Length 14 1 2 Width 5 3 4 Height 18 Shipping Weight 18 Lbs Voltage c 120V 50 60Hz Power Consumption d 14 Watts Max O...

Page 16: ...16 REPLACEMENT PARTS Bio Logic ULTRAVIOLET WATER PURIFIER Figure 10 Exploded View Bio Logic 1 5...

Page 17: ...1 10 1201A 3 Germicidal Lamp 1 05 1366 R 4 Static Gland Nut 2 25 1492D 5 Teflon Washer 2 25 3023A 6 Rubber O ring Quartz Sleeve 2 00 1023A 7 Quartz Sleeve 1 15 1700A 8 Chamber Head 2 with Ground Termi...

Page 18: ...18 REPLACEMENT PARTS Bio Logic Pure Water Pack Figure 11 Exploded View Bio Logic Pure Water Pack...

Page 19: ...4509 9 Male Connector x3 8 NPTF John Guest 4 25 4513 10 Pipe Nipple 3 8 x1 Long PVC 1 25 4510 11 Tubing OD x 24 Long 1 25 4515 12 Saddle Valve fits 3 8 Copper Tubing 1 25 4511 13 Faucet Long Reach Sp...

Page 20: ...E No attempt has been made to determine the patent status of applications illustrated or described in this publi cation Inclusion in this publication of any design or method of use which may be patent...

Reviews: