PRODUCT APPLICATION

C

ONSTRUCTION

All filtration and disinfection components, of the 

Bio-Logic

®

Pure Water Pack

, are conveniently mounted 

on a single, stainless steel, mounting bracket.

The system is designed to mount on a vertical surface, a secure (stud or concrete) wall or a cabinet wall, by the 
system-mounting bracket.

The faucet, supplied with the system, is a low lead, stainless steel faucet, with a hand operated, spring closed lever.
The faucet can be locked in the “ON” position by pushing the lever up locking it against the spout.

The water purifier's dual chamber heads are removable and may be rotated independently, which aids in the 
installation, maintenance or the retrofitting of an existing system.

The water purifier's chamber, and chamber heads are electropolished and passivated type 316 stainless steel.

Easy-off end caps allow for quick and easy lamp change, without disconnecting the system from the water supply 
or draining the purifier. No tools are required.

P

RINCIPLE OF

O

PERATION

The 

Bio-Logic

®

Pure Water Pack

filter system removes sediment, rust, scale, and particulates, while 

reducing tastes, odors, organic chemicals and turbidity. The 

Bio-Logic

®

is the ultraviolet disinfection element of the

Pure Water Pack

.

The 

Bio-Logic

®

design has been carefully conceived to provide adequate germicidal dosage throughout the disinfec-

tion chamber. The dosage, as it applies to ultraviolet disinfection, is a function of time, and the intensity, of ultraviolet
radiation, to which the water is exposed. The exposure time, in seconds, is the total time it takes the water to flow
through the disinfection chamber, exposing it to the germicidal lamp. Exposure time is related to the flow rate; the
higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The ultravio-
let intensity is the amount of energy, per unit time, emitted by the germicidal lamp. The operation of the 

Bio-Logic

®

is as follows:
1.

Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall.

2.

Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp.

3.

The LED indicator light, located on the ballast, provides visual indication of germicidal lamp operation.

4.

Water leaving the purifier is instantly ready for use, no further contact time is required.

L

IMITATION OF

U

SE

The water purifier is intended for the use with visually clear water, not colored, cloudy or turbid. 
See “

Water Quality

” section below.

The water purifier is 

NOT

intended for the treatment of water that has an obvious contamination or intentional source,

such as raw sewage; nor is the unit intended to convert wastewater to microbiologically safe drinking water.

W

ATER

Q

UALITY

Water quality plays a major role in the transmission of germicidal ultraviolet rays. It is recommended that the water
does not exceed the following maximum concentration levels:

Table 1 - Maximum Concentration Levels

Effectively treating water with higher concentration levels than listed above can be accomplished, but may require
added measures to improve water quality to treatable levels. If, for any reason, it is believed the ultraviolet transmission
is not satisfactory, contact the factory.

Manganese:

0.05mg/l

Total Suspended Solids:

10 mg/l

pH:

6.5 - 9.5

Color:

None

Hardness:

6 GPG or 102.6 PPM

Iron:

0.3 mg/l

Summary of Contents for BIO-1.5

Page 1: ...auge NY 11788 USA 631 273 0500 Fax 631 273 0771 e mail info ultraviolet com Extensive Product Information Available at www ultraviolet com Document No 98 1124B6 Revised December 2010 2002 2010 Atlanti...

Page 2: ...instructions generally describe the installation operation and maintenance of the Bio Logic Pure Water Pack Questions that are not specifically answered by these instructions should be directed to th...

Page 3: ...RUCTIONS WARNING To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL safety instructions 2 Do not use this system for other than its inten...

Page 4: ...flow through the disinfection chamber exposing it to the germicidal lamp Exposure time is related to the flow rate the higher the flow rate the lower the exposure time or the lower the flow rate the h...

Page 5: ...thod of replacing the quartz sleeve in your water purifier The Bio Logic Pure Water Pack is shipped with the lamp packed separately Keep the lamp aside for installation once the Pure Water Pack has be...

Page 6: ...t be connected to the cold water line only 4 The system should be located as close to the faucet as possible 5 CAUTION As with any water handling device the water purifier should be located in an area...

Page 7: ...turning the T handle clockwise until it is firmly seated The valve is CLOSED in this position 4 Open the cold water supply valve or main valve check for any signs of leaks around valve connection 5 In...

Page 8: ...Lifting the handle of the faucet will lock the faucet in the ON position while holding the handle down the faucet is ON the faucet well shut off when the handle is released Slowly open the saddle valv...

Page 9: ...se of this system For any questions concerns or technical assistance regarding this system or any of our other products contact our application specialists Contact options can be found in the User Ass...

Page 10: ...er purifier 2 Shut off water supply to the system by closing the supply valve Open the system faucet and allow the system to drain 3 Release the pressure in the filter housing by pressing the red pres...

Page 11: ...to water purifier until lamp and both easy off end caps have been properly reinstalled 7 Reattach the ground connector to the grounding tab of the chamber and restore power to the system DISPOSAL OF M...

Page 12: ...ochloric acid NOTE Follow all manufacturer s instructions and precautions when handling chemicals 8 Reassemble in reverse order Make sure the quartz sleeve protrudes an equal distance past each thread...

Page 13: ...the head clamp around the flared ends of the head and chamber Install the 1 4 nut and tighten using a 7 16 wrench until approximately 7 8 to 1 of the bolt protrudes past the nut 11 Carefully insert qu...

Page 14: ...ir bubbles Water contains black particles New carbon filter cartridges Open system faucet allow water to run purging the contain activated carbon carbon particles from the cartridge until water is cle...

Page 15: ...John GuestTM Connector Number of Lamps 1 Lamp Model No 05 1366 R Quartz Sleeve Yes Length 14 1 2 Width 5 3 4 Height 18 Shipping Weight 18 Lbs Voltage c 120V 50 60Hz Power Consumption d 14 Watts Max O...

Page 16: ...16 REPLACEMENT PARTS Bio Logic ULTRAVIOLET WATER PURIFIER Figure 10 Exploded View Bio Logic 1 5...

Page 17: ...1 10 1201A 3 Germicidal Lamp 1 05 1366 R 4 Static Gland Nut 2 25 1492D 5 Teflon Washer 2 25 3023A 6 Rubber O ring Quartz Sleeve 2 00 1023A 7 Quartz Sleeve 1 15 1700A 8 Chamber Head 2 with Ground Termi...

Page 18: ...18 REPLACEMENT PARTS Bio Logic Pure Water Pack Figure 11 Exploded View Bio Logic Pure Water Pack...

Page 19: ...4509 9 Male Connector x3 8 NPTF John Guest 4 25 4513 10 Pipe Nipple 3 8 x1 Long PVC 1 25 4510 11 Tubing OD x 24 Long 1 25 4515 12 Saddle Valve fits 3 8 Copper Tubing 1 25 4511 13 Faucet Long Reach Sp...

Page 20: ...E No attempt has been made to determine the patent status of applications illustrated or described in this publi cation Inclusion in this publication of any design or method of use which may be patent...

Reviews: