End of Life Management 

 
• There are no components which contain stored electrical energy after the device has 
been shut off 
• Does not contain hazardous substances requiring special handling and treatment 
• Dispose of in an environmentally responsible manner in accordance with regional 
requirements 
• Contact Bio Compression Systems if you have questions or concerns regarding 
disassembly and disposal 
 

Manufacturer’s EMC Declaration 

Electromagnetic Emissions 
 

Emissions

 

Compliance 

Electromagnetic Environment - Guidance

 

RF emissions 
CISPR 11 

Group 1 

The device uses RF energy only for its internal functions.  Therefore, its RF 
emissions are very low and are not likely to cause any interference in nearby 
electronic equipment. 

RF emissions 
CISPR 11 

Class B 

The  device  is  suitable  for  use  in  all  establishments,  including  domestic 
establishments and those directly connected to the public low voltage power supply 
network that supplies building used for domestic purposes. 

Harmonic emissions 
IEC 61000-3-2 

Not 
applicable 

Voltage fluctuations/ 
flicker emissions 
IEC 61000-3-3 

Not 
applicable 

 

Electromagnetic Immunity 

 

Immunity Test 

Immunity Test Level 

IEC 61000-4-2 Electrostatic Discharge Immunity 

±8kV contact, ±2, 4, 8kV air discharge 

IEC 61000-4-3 Radiated RF Field Immunity 

80MHz 

– 2.7GHz, 10V/m, AM 80% at 1kHz 

IEC 61000-4-3 Proximity Fields from RF Wireless 
Communications Equipment 

IEC 60601-1-2, Section 8.10, Table 9 

IEC 61000-4-4 Electrical Fast Transients 

±2kV/100kHz power, ±1kV/100kHz signal 

IEC 61000-4-5 Surge Immunity 

±0.5, 1kV line to line, ±0.5, 1, 2kV line to ground 

IEC 61000-4-6 Conducted RF Immunity 

150kHz - 80MHz, 3V

RMS

 in whole range, 6V

RMS

 in amateur radio and 

ISM, AM 80% at 1kHz 

IEC 61000-4-8 Magnetic Field Immunity 

30A/m, 50 or 60Hz 

IEC 61000-4-11 Voltage Dips 

0% U

T

 per 0.5 cycles, 0% U

T

 per 1.0 cycle, 70% U

T

 per 25/30 

cycles 

IEC 61000-4-11 Voltage Interruptions 

0% U

T

 per 250/300 cycles 

 
 

 

Summary of Contents for IC-1545-DL Multi-Flo DVT Combo

Page 1: ...Intermittent Pneumatic Compression Device Operating Instructions Quality Medical Products Since 1983...

Page 2: ...2...

Page 3: ...n 4 Intended Use 4 Device Description and Operating Principle 5 Warnings and Precautions 6 Operating Instructions 8 Accessories 11 Product Specifications 11 Environmental Specifications 12 Symbol Glos...

Page 4: ...Cold Compression Intended to help reduce pain and swelling after surgery Enhances faster healing and tissue regeneration required by the body Contraindications Use of this device is contraindicated fo...

Page 5: ...atment A physician is required to prescribe these settings but general guidelines are listed below It is ultimately the physician s responsibility to prescribe the setting and it should be written on...

Page 6: ...of electric shock burns fire injury or improper treatment read the entire instruction manual before operating this device Use of accessories or a power cord not specified or provided by Bio Compressi...

Page 7: ...ing heat or cold When Using This Product Examine the device accessories and power cord for damage before using or cleaning Handle garments with care do not fold or crease use near a heat source handle...

Page 8: ...y surface pump must be close enough for the controls to be reached during use Plug power cord into outlet Remove garments from plastic bag unroll and spread flat Place gel insert flat in freezer for 4...

Page 9: ...lugged if more thorough pump cleaning or garment disinfection is desired use the following directions Pump tubing and calf garment cleaning Unplug and wipe down using a damp not wet soft cloth with mi...

Page 10: ...Check to see if the pump is plugged in 2 Unplug and examine power cord for damaged if damaged contact Bio Compression Systems 3 Check circuit breaker to make sure outlet has power 4 Contact Bio Compr...

Page 11: ...tion IP20 Mains Isolation Unplug Mode of Operation Continuous Essential Performance The pump s cyclical inflation and deflation of the garment s Cycle Time 60 10 seconds Inflation 15 seconds calf mode...

Page 12: ...ices when they are not being used saves electricity Unplug the pump when not in use unplugging electronic devices when they are not being used saves electricity Do not clean garment soiled this minimi...

Page 13: ...nd those directly connected to the public low voltage power supply network that supplies building used for domestic purposes Harmonic emissions IEC 61000 3 2 Not applicable Voltage fluctuations flicke...

Page 14: ...c shock Restricted to sale by or on the order of a physician Complies with the Waste Electrical and Electronic Equipment Directive WEEE Directive Serial number Complies the European Medical Device Reg...

Page 15: ...7074 USA Phone 1 201 939 0716 Toll Free Phone US 800 888 0908 E mail biosystems biocompression com Website www biocompression com When contacting us please have your model number and serial number rea...

Page 16: ...16 L 008 I EN 2020 04...

Reviews: