switch. When power is applied to the device - BATTERY (+) /VCC -, the device remains off. It will not turn on until the
ignition pin - ACC / IGNITION - sends a signal (+12 V or +24 V).
Similarly, if the ignition signal deactivates after the device has been turned on, the device will remain on for the peri-
od of time configured through the “set ignition-off-powerdown-timer <value> ” command.
*
*p 4
Config>set ?
application-active
Permits you to select the code used to boot the router
console
Set console configuration
contact-person
Assign a name or identification to the contact-person
data-link
Type of data link for a WAN line
default-conf
Restores the default configuration
file-cfg
Configure a configuration file as active
ftp
Permits you to access the FTP configuration menu
host-location
Physical location of the router
hostname
Assign a name to a device
ignition-off-powerdown-timer
Configure the time to router power down after car
ignition off
inactivity-timer
Configure the maximum inactivity time
login
Configure login options
password
Configure the device access password
pool
Number of bytes assigned to each memory pool
schedule-restart
Allows to configure router reset schedule
telnet
Access the TELNET protocol configuration
web-probe
Access the Web probe configuration
Config>set ignition-off-powerdown-timer ?
<1..1440>
Power down timeout in minutes
disabled
Disable ignition off power down timer
Config>set ignition-off-powerdown-timer 10
Config>
For further information on this command, please see the following manual: bintec Dm704-I Configuration and Monit-
oring.
Note
The Power Management feature is always enabled.
In order to disable the Power Management feature, connect the IGNITION signal to the VCC / BAT-
TERY (+). For further information see
Connecting the power cable to the vehicle
on page 10 and
on page 11
3.4 RESET Button
The following sections describe the RESET button features.
Fig. 11:
Reset button
3 Components and power supply
bintec elmeg GmbH
12
bintec H2 Aut