BINMASTER SMARTBOB TS1 Installation And Operating Instructions Manual Download Page 7

FIGURE 4a -- WIRED RS 485 FROM COMPUTER TO TS1 UNITS

FIGURE 4b -- WIRELESS FROM COMPUTER TO ONE TS1 WITH A RADIO MODULE, 

WIRED RS 485 TO OTHER TS1’s WITHOUT RADIO MODULES

NOTE: 

  There can be only

 one

 TS1 unit having a wireless modem connected to each wired RS-485 net-

work.  Do not connect multiple TS1 units with wireless modems to the same RS-485 network.

FIGURE 4c -- WIRELESS FROM COMPUTER TO ALL TS1’s WITH RADIO MODULES

2.5  WIRELESS MODEM

The optional wireless modem allows units to communicate without having interconnect-
ing wires.  A system may consist of all TS1 units having wireless modems or just one 
TS1 unit with a wireless modem and other TS1 units without wireless modems hard 
wired to it with RS-485 cable.  In such a case where one TS1 with a wireless modem 
drives a hardwired RS-485 network, the TS1 with the wireless modem must have both of 
its BIAS jumpers placed in the ON position and its TERM switch in the ON position.  All 
other units on the network should have their BIAS jumpers in the OFF position.  The last 
unit on the RS-485 network should have its TERM switch ON and all other units, except 
the one with the wireless modem, should have their TERM  switch OFF.

RS 485 CONVERTER

TS1 with RADIO MODULE

TS1 without RADIO MODULE

TS1 without RADIO MODULE

ALL TS1 UNITS HAVE 
RADIO MODULES

Jamieson Equipment Company 

www.jamiesonequipment.com 

toll free 800.875.0280

Summary of Contents for SMARTBOB TS1

Page 1: ...RTBOB REMOTE UNIT SMARTBOB REMOTE UNIT SMARTBOB REMOTE UNIT SMARTBOB REMOTE UNIT INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Jamieson Equipment Company www jamiesonequipment com toll...

Page 2: ...VERRIDE 10 2 8 PROTO JUMPER SETTING 10 3 0 TESTING THE REMOTE OPERATION 11 3 1 TS1 MANUAL CYCLE AND RETRACT SWITCHES 11 3 2 LED INDICATORS 11 3 3 TROUBLESHOOTING 12 4 0 WARRANTY AND CUSTOMER SERVICE 1...

Page 3: ...C to 60 C without heater 20 F to 140 F 28 C to 60 C with optional heater Measurement Range 30 Feet Maximum Accuracy 2 or 7 inches Resolution 0 1 ft 0 03m Communication RS 485 Half Duplex Wiring Distan...

Page 4: ...diagnostic purposes Figures 4a through 4c illustrate a few possible system configurations for both hard wired and wireless installations Many other configurations to fit specific needs are possible 2...

Page 5: ...ght built up in the TS1 It is recommended that both the power and the RS 485 communication cable be ran in metal conduit FIGURE 2 2 3 RS 485 NETWORK WIRING RS 485 network cable consists of a twisted p...

Page 6: ...1 or SmartBob SBRXII units the TS1 with the wireless modem should have its BIAS jumpers ON and its TERM switch ON All other TS1 units must have their BIAS jumpers OFF and except for the very last unit...

Page 7: ...ms or just one TS1 unit with a wireless modem and other TS1 units without wireless modems hard wired to it with RS 485 cable In such a case where one TS1 with a wireless modem drives a hardwired RS 48...

Page 8: ...inted on the TS1 circuit board above the switch The Binary value of each lever in the up ON position are added together to give the address number Consult the following chart to assist in determining...

Page 9: ...6 OFF OFF OFF OFF OFF ON ON OFF 32 OFF OFF OFF OFF OFF ON OFF OFF 97 ON OFF OFF OFF OFF ON ON OFF 33 ON OFF OFF OFF OFF ON OFF OFF 98 OFF ON OFF OFF OFF ON ON OFF 34 OFF ON OFF OFF OFF ON OFF OFF 99 O...

Page 10: ...optional if not used leave the factory installed jumper in the termi nal block FIGURE 6 2 8 PROTO JUMPER SETTING The TS1 is capable of operating in two different modes as selected by the PROTO jumper...

Page 11: ...D This switch allows the motor to run forward and let out line to lower a bob It only runs while the switch is held in 3 2 LED INDICATORS BUSY This LED indicates when data traffic is present on the RS...

Page 12: ...eplace any part of this equipment found to be defective provided such part is delivered prepaid to the factory Manufacturer s obligation is limited to the cost of material and labor to repair or repla...

Page 13: ...y vessel 3 Thread the same end of the cable through the hole on the front of the supply pul ley flange and tie a knot to secure the cable to the supply pulley 4 Located on the PC board is a button lab...

Page 14: ...tight so it cannot rewind The motor should now be shut off 2 From the throat of the TS1 measure the height of your vessel or the maximum distance you want the bob to travel Cut the cable at this dista...

Page 15: ...aterial that is stored in the storage bin Total weight of the Bob when full should be 16 oz The B7 is made from an engi neering plastic which will not damage the material handling auger in the unlikel...

Page 16: ...b Remote Mounting Template 5 16 Diameter Through Hole 6 Holes Equally Spaced 4 1 4 Diameter Cutout 5 1 8 Diameter Bolt Hole Circle Jamieson Equipment Company www jamiesonequipment com toll free 800 87...

Page 17: ...plate 7 00 inch Bolt Circle 5 16 Diameter Through Hole 6 holes equally spaced on a 7 00 Bolt Circle 7 00 Diameter Bolt Hole Circle 4 1 2 Diameter Cutout Jamieson Equipment Company www jamiesonequipmen...