Page 2
© ITW Inc 2007
AIR MOTOR DRIVES and AGITATORS for
PRESSURE FEED TANKS
IMPORTANT: Read and follow all instructions and SAFETY PRECAUTIONS
before using this equipment. Retain for future reference.
DESCRIPTION
This manual covers the following models;
QS-5012-CE
Air motor drive with 15:1 gear reduction.
Includes air adjusting for speed control with hose and
fittings for tank regulator connection.
QMS-431-CE, 433-CE and 434-CE
Agitator for use with
QS-5012-CE Gear reduction drive on 2, 10 and 15 gall
tanks models. Alternatively can be used without a drive
motor for manual operation.
QMS-430-CE
direct drive air motor and Agitator. Used on
83S-211-CE SS Pressure Feed tanks. Includes air adjusting
for speed control with hose and fittings for tank regulator
connection.
PT-427/418-CE
direct drive air motor for use on 83C and
83Z-211-CE pressure feed tanks.
PT-419/428-CE
agitator shaft and impellor for use with PT-
427-CE/418-CE.
All models are suitable for use with flammable coating
materials and for use in a Zone 1 classified hazardous
area.
These Agitators are CE marked in accordance with the
ATEX Directive 94/9/EC for hazardous area use and
Machinery Safety Directive 98/37/EC.
These Agitators are designed for use with Pressure
Tanks. These are pressure containers to supply liquid
material at a constant preset pressure up to a maximum
of 7.0 bar. Read all the information contained in this
bulletin
and the pressure feed tank bulletin before
attempting installation.
SBBI-E-19-095
Part Number
ATEX classification
Type approval certificate Number
QS-5012-CE
II 2 G c T4
TRL06ATEX21105X
QMS-431-CE, 433-CE & 434-CE
II 1/2 G c T4
TRL06ATEX21107X
QMS-430-CE
II 1/2 G c T4
TRL06ATEX21106X
PT-427-CE/418-CE & PT-419-CE/428-CE
II 1/2 G c T4
TRL06ATEX21109X
All Models
Ambient temperature range +1ºC to 40ºC (34 to 104ºF)
All models are certified for use in Hazardous areas, Zone 1 for areas around the tank and Zone 0 for
inside the tank. Temperature class T4 (135
˚
C).