EC
Declaration
of
Conformity
We:
ITW
Finishing
UK,
Ringwood
Rd.,
Bournemouth,
Dorset,
BH11
9LH,
UK
As
the
manufacturer
of
the
items
listed
below:
Piston
Pumps
MX412
MX432
Declare,
under
our
sole
responsibility,
that,
the
equipment
to
which
this
document
relates
is
in
conformity
with
the
following
standards
or
other
normative
documents:
EN
13463
‐
1:2009,
EN
13463
‐
5:2005,
EN
982:1996
+
A1:2008,
EN
983:1996
+
A1:2008
and
EN
12621:2006
And
thereby
conform
to
the
protection
requirements
of
Council
Directive
98/37/EC
relating
to
Machinery
Safety
Directive
and
council
Directive
94/9/EC
relating
to
Equipment
and
Protective
Systems
intended
for
use
in
Potentially
Explosive
Atmospheres
;
CE
Ex
2
II
Gc
T4
Issued
on:
1st
July
2009
Authorized
by:
Technical
file
lodged
with;
TRL
Compliance
Ltd
(Notified
Body
0891)
Moss
View
Nipe
Lane
Up
Holland
WN8
9PY,
UK
HAZARD
CAUSE
SAFEGUARDS
EXPLOSION
STATIC ELECTRICITY Use of this
equipment in a potentially explosive
atmosphere.
Vapors from flammable liquids can
catch fire or explode from static
electricity discharges.
1. If installing this equipment in a potentially explosive atmosphere, check
the ATEX equipment category and temperature ratings meet the
requirements for the zoned area. 2. Check electrical continuity of the air
supply to earth — should be no greater than 10
6
.
3. Electrically bond all metallic equipment to earth. Should be no greater
than 1 .
SPECIAL
Over pressurization of
equipment can cause
equipment failure or injury.
Use lubricating medium
resistant to carburisation. Improper
operation or maintenance may create
a hazard.
1. Do not exceed the stated maximum working pressures
and motor speed as specified in this manual.
2. Only a suitably approved static dissipating or
conductive air supply hoses shall be attached to the
equipment and terminated to the air supply.
3. Air supplies (compressors, etc.) shall be sited in a nonhazardous area
with a filter on the air intake system to prevent the ingress of dust or similar
foreign material into the parts where compression takes place.
4. Use lubricating medium resistant to carburisation and has an auto ignition
temperature of more than 185ºC for T4 equipment.
5. User shall ensure all metallic parts of the equipment are suitably bonded
to earth. Should be no greater than 1 .
CONDITIONS
FOR SAFE USE
REQUIRED
BY ATEX
CERTIFICATION