background image

 

 

 

 

 

 

 

 

6.

 

Remove

 

the

 

spray

 

tip

 

from

 

the

 

gun

 

and

 

point

 

the

 

gun

 

into

 

the

 

tank.

 

Unlock

 

the

 

safety

 

lever

 

on

 

the

 

gun.

 

Operate

 

the

 

gun

 

trigger

 

and

 

close

 

the

 

high

 

pressure

 

ball

 

valve

 

(0114

019091).

 

The

 

spray

 

material

 

will

 

now

 

flow

 

through

 

the

 

high

 

pressure

 

filter,

 

the

 

fluid

 

hose

 

and

 

the

 

gun,

 

back

 

into

 

the

 

tank.

   

 

7.

 

Release

 

the

 

gun

 

trigger

 

and

 

set

 

the

 

working

 

pressure

 

at

 

the

 

regulator.

   

WORK

 

STOPPAGES

 

 

 

!

 

CAuTiO
N

 

 

If

 

working

 

with

 

2

K

 

spray

 

material,

 

you

 

must

 

note

 

the

 

given

 

pot

 

life

 

and

 

follow

 

it

 

precisely.

 

Within

 

this

 

time,

 

the

 

unit

 

must

 

be

 

carefully

 

cleaned

 

and

 

rinsed

 

with

 

the

 

recommended

 

solvent.

 

There

 

must

 

be

 

no

 

residue

 

left

 

in

 

the

 

pump,

 

the

 

high

 

pressure

 

filter

 

or

 

the

 

gun.

 

 

 

For

 

work

 

stoppages

 

of

 

between

 

10

 

and

 

30

 

minutes,

 

please

 

proceed

 

as

 

follows:

   

 

  

1.

 

Lock

 

the

 

safety

 

lever

 

on

 

the

 

gun.

 

 

 

2.

 

Shut

 

off

 

the

 

compressed

 

air

 

supply

 

by

 

closing

 

the

 

ball

 

valve.

   

 

SHUT

DOWN

 

 

 

1.

 

Close

 

the

 

ball

 

valve

 

for

 

the

 

compressed

 

air

 

supply.

   

 

2.

 

Make

 

sure

 

that

 

the

 

flow

 

hose

 

(0110

009103)

 

is

 

still

 

directed

 

into

 

the

 

spray

 

material

 

tank.

 

Carefully

 

open

 

the

 

high

 

pressure

 

ball

 

valve

 

(0114

019091)

 

to

 

reduce

 

the

 

pressure

 

in

 

the

 

pump

 

and

 

in

 

the

 

high

 

pressure

 

filter.

   

 

3.

 

Remove

 

the

 

spray

 

tip

 

from

 

the

 

gun.

   

 

 

CAUTION

 

!

 

If

 

working

 

with

 

waterborne

 

material,

 

the

 

BINKS

 

pump

 

must

 

again

 

be

 

thoroughly

 

rinsed

 

with

 

water

 

before

 

it

 

is

 

started

 

up.

 

7.

 

Clean

 

the

 

filter

 

of

 

the

 

suction

 

system.

   

 

6.

 

Clean

 

the

 

filter

 

element

 

of

 

the

 

high

 

pressure

 

filter

 

(0110

009130).

 

 

 

CAUTION

 

!

 

Do

 

not

 

allow

 

spray

 

material

 

or

 

solvent

 

to

 

soak

 

into

 

the

 

ground.

 

 

CLEANING

 

YOUR

 

BINKS

 

PUMP

 

 

5.

 

Lock

 

the

 

safety

 

lever

 

on

 

the

 

gun.

 

 

4.

 

Point

 

the

 

gun

 

into

 

the

 

tank

 

of

 

spray

 

material

 

and

 

operate

 

the

 

trigger

 

to

 

reduce

 

any

 

pressure

 

which

 

may

 

still

 

exist

 

in

 

the

 

fluid

 

hose

 

and

 

in

 

the

 

gun.

   

 

 

1.

 

Clean

 

the

 

pump

 

and

 

the

 

suction

 

system

 

from

 

the

 

outside.

 

Immerse

 

the

 

suction

 

system

 

in

 

the

 

tank

 

of

 

solvent.

   

 

2.

 

Clean

 

the

 

fluid

 

tip/tip

 

system

 

as

 

described

 

in

 

the

 

service

 

bulletin

 

of

 

the

 

spray

 

gun.

 

We

 

recommend

 

to

 

soak

 

the

 

fluid

 

tip

 

in

 

solvent.

   

 

3.

 

Unlock

 

the

 

safety

 

lever

 

of

 

the

 

gun

 

without

 

fluid

 

tip.

 

Operate

 

the

 

gun.

 

Close

 

the

 

high

 

pressure

 

ball

 

valve

 

(0114

01909).

 

Set

 

the

 

air

 

inlet

 

pressure

 

to

 

1

 

bar

 

(14.5

 

psi)

 

and

 

slowly

 

open

 

the

 

ball

 

valve.

 

Let

 

the

 

solvent

 

run

 

through

 

the

 

system

 

so

 

that

 

the

 

spraying

 

material

 

can

 

rinse

 

out.

   

 

4.

 

Let

 

the

 

solvent

 

run

 

through

 

the

 

system

 

for

 

a

 

couple

 

of

 

minutes

 

until

 

the

 

solvent

 

runs

 

clear

 

through

 

the

 

gun.

 

Close

 

the

 

ball

 

valve

 

and

 

lock

 

the

 

safety

 

lever

 

of

 

the

 

gun

 

 

5.

 

Clean

 

the

 

gun

 

from

 

the

 

outside

 

and

 

check

 

the

 

filter

 

on

 

the

 

handle

 

(if

 

mounted).

   

 

8.

 

We

 

recommend

 

keeping

 

the

 

pump

 

filled

 

with

 

liquid.

   

 

 

3.

 

Briefly

 

open

 

the

 

high

 

pressure

 

ball

 

valve

 

(0114

019091),

 

taking

 

care

 

that

 

the

 

return

 

flow

 

hose

 

(0110

009103)

 

is

 

not

 

pointed

 

at

 

other

 

people

 

or

 

at

 

yourself,

 

until

 

the

 

pressure

 

has

 

reduced.

 

Then

 

close

 

the

 

high

 

pressure

 

ball

 

valve

 

again.

   

 

4.

 

Clean

 

the

 

outside

 

of

 

the

 

spray

 

nozzle

 

from

 

spray

 

material

 

residue.

   

 
 

STARTUP

 

AND

 

OPERATION

 

6.

 

Remove

 

the

 

suction

 

system

 

from

 

the

 

spray

 

material.

   

 

77

2923R

 

page

 

6

 

of

 

16

   

 

 

Summary of Contents for MX412

Page 1: ...m air inlet pressure 8 bar 116 psi Maximum fluid pressure 96 bar 1390 psi Displacement per cycle 24 cc 0 8 oz Output 60 cycles min 1 4 L m 0 4 gal m Air consumption 20 cycles min 62 5 LPM 2 2 SCFM Max...

Page 2: ...of certain pacemakers AUTOMATIC EQUIPMENT Automatic equipment may start suddenly without warning INSPECT THE EQUIPMENT DAILY Inspect the equipment for worn or broken parts on a daily basis Do not ope...

Page 3: ...g the system Operate the pump at the lowest possible pressure GENERAL WARNINGS 1 NEVER leave a pressurized sprayer unattended 2 Periodically inspect all hoses for leaks and or abrasions and tighten al...

Page 4: ...his equipment in a potentially explosive atmosphere check the ATEX equipment category and temperature ratings meet the requirements for the zoned area 2 Check electrical continuity of the air supply t...

Page 5: ...5 Open the ball valve and set the air regulator 0115 010183 to approximately 1 bar 14 5 psi The suction system now draws in the solvent The solvent runs back to the solvent tank through the high pres...

Page 6: ...f the high pressure filter 0110 009130 CAUTION Do not allow spray material or solvent to soak into the ground CLEANING YOUR BINKS PUMP 5 Lock the safety lever on the gun 4 Point the gun into the tank...

Page 7: ...4 4 4 4 0115 010030 M8 HEX NUT 4 4 4 4 5 0115 010031 M8 LOCKWASHER 4 4 4 4 6 0115 010035 M8 PLAIN WASHER 4 4 4 4 7 MX412PL MX412 BARE PUMP ASSEMBLY PTFE LEATHER 1 0 1 0 77 2906 EU 8 MX412PP MX412 BAR...

Page 8: ...4 4 3 0115 010030 M8 HEX NUT 4 4 4 4 4 0115 010031 M8 LOCKWASHER 4 4 4 4 5 0115 010035 M8 PLAIN WASHER 4 4 4 4 6 MX412PL MX412 BARE PUMP ASSEMBLY PTFE LEATHER 1 0 1 0 77 2906 EU 7 MX41 MX412 BARE PUMP...

Page 9: ...2 0115 010227 SOCKET HEAD CAP SCREW 4 4 4 4 3 MX412PL MX412 BARE PUMP ASSEMBLY PTFE LEATHER 1 0 1 0 77 2906 EU 4 MX412PP MX412 BARE PUMP ASSEMBLY PTFE 0 1 0 1 77 2906 EU 5 0115 010180 AIR ASSIST AIR...

Page 10: ......

Page 11: ...PSI 0 4 BAR 1 7 0115 010194 PANEL MOUNT NUT 2 8 0115 010334 MINI BALL VALVE 1 9 0115 010333 DM ADAPTER 1 10 0115 010193 DUAL REGULATOR PANEL 1 11 0115 010191 PANEL MOUNT GAUGE 0 60 PSI 0 4 BAR 1 12 01...

Page 12: ...OCK 1 6 0115 010338 PORT PLUG 1 7 0115 010199 SINGLE REGULATOR PANEL 1 8 0115 010194 PANEL MOUNT NUT 1 9 0115 010334 MINI BALL VALVE 1 10 0115 010333 DM ADAPTER 1 11 0115 010192 PANEL MOUNT GAUGE 0 16...

Page 13: ...5 010100 TRIPOD ASSEMBLY PARTS LIST 0115 010186 CART ASSEMBLY PARTS LIST ADDITIONAL STRAINERS AVAILABLE sold separately 0114 014068 50 mesh 0114 014221 70 mesh ITEM PART NO NO DESCRIPTION 1 0115 01010...

Page 14: ...luded 0909 4400 LF0000 Trans Tech no tip included TWIST TIP VERSIONS 0909 4400 HT0000 HVLP no tip included 0909 4400 LT0000 Trans Tech no tip included TROLLEY ASSEMBLY 0115 010186 AIR CONTROLS 0115 01...

Page 15: ...NOTES...

Page 16: ...ance Tel 33 4 75 75 27 00 Fax 33 4 75 75 27 59 Email mkt itwsf com ITW Oberfl chentechnik GmbH Justus von Liebig Stra e 31 D 63128 Dietzenbach Germany Tel 49 0 6074 403 1 Fax 49 0 6074 403 300 Email m...

Reviews: