SB-6-HGB-H
12/40
INSTALLATION
The regulators must be fitted in horizontal position to remove heavy fluid particle deposit. The
riser tube for manometer must be in vertical position. The manometer will be protected by air
staying into the top of the riser tube. A good sealing ought to be done on the connectors so to
remove any air leakage to protect the manometer.
Connect the fluid supply line, coming from pump or pressure feed tank, under the regulator at
the ¼
’
’
BSP or 3/8
’
’
NPS/BSP universal (See on page 11 depend of version used).
Connect the regulated fluid line, to supply one or two spray gun, side port of the regulator at the
¼
’
’
BSP or 3/8
’
’
NPS/BSP universal (See on page 11 depend of version used).
Swivel connector female is used for
“
CO
”
version on remote control.
The regulator must be earthed to dissipate any electrostatic charge which may be created by
fluid or air flows. This can be achieved in using one of the screw ref 3A or 3B.
Electrical bond from the regulator to earth should be checked with an ohmmeter.
A resistance of less than 10
6
Ohms is recommended.
Assume that during the installation, the regulator will filled completely the cavity under the
diaphragm, this is to obtain the full accurate regulation specially in use at lower fluid flow
delivery.
CAUTION
It is recommended that at the initial installation the material supply line should not be flushed
through the regulator because pipe compound chips, scale, etc. may lodge on the valve seat
USE AN IN LINE FILTER.
OPERATION
Manuel regulator
Fluid pressure adjustment is done with the specific
manual key. Insert the square side key into the central top
hole of the regulator manual. See Fig A
Screw to increase fluid pressure, unscrew to decrease.
To flush the regulator for cleaning operation introduce the
cylindrical side of the key into the regulator and screw at
maximum to push the pin on the membrane support and
open the regulator in order to have optimum flushing fluid
flow
Pneumatic adjustment regulator
For models HGB-510-R1, R2 or R4.
The fluid pressure regulation is adjusted by remote air
pressure regulator, for that connect Rilsan tube on the top
connector on cover. To flush the regulator, connect air tube
on the side connector (R1/R2/R4) and set the air pressure to
full open the valve regulator. It
’
s useful to fit the air
regulator close to the fluid regulator to obtain the accurate
regulation at a low fluid flow. If it
’
s not the case, you can
obtain this accurate regulation in piercing the Rilsan tube
with sewing needle near of the connector to create a small
air leakage.
To flush the fluid line with solvent, connect the flushing air
command to the right connector on the side of the regulator.
DO NOT EXCEED THE FLUSHING AIR COMMAND MORE THAN 1 BAR OVER THE
SOLVENT PRESSURE.