10: Catalyst Pump
The catalyst pump meters catalyst to the mix manifold. Using flow rate input from the gear flow meter,
the system controller directs the pump’s stepper motor to precisely dispense catalyst at the required ratio.
With very low-speed capability and true positive displacement, the catalyst pump can accurately provide
ratios from 1:1 to 100:1, depending on flow rate. At a low ratio (such as 10:1), flow rates should not
exceed 1000cc/min so as to not overspeed the pump.
Linear Potentiometer
ACME Shaft
Stepper Linear
Actuator
Bearing / Position Indicator
Pressure
Transducer
Oil Reservoir
Pump
Fluid Inlet
Pump Fluid
Outlet
Drive Assembly
Fluid Assembly
240-3208