8
Checking before Troubleshooting
Check the following if the machine cannot operate or the operation is not smooth
:
1)
If the
START BUTTON LED
is OFF:
*Check if the power cord is plugged.
*Check if the power switch is turned OFF.
→ Plug the power cord, and turn ON the power switch.
2) If
the
FEED BUTTON LED
is blinking:
*Check if the band is fed.
*Check if the band is fed well to the hold plate.
→ Press the
feed button
to set the band to its initial position.
3) If the banding is not performed even if an object is put on the object sensor in
auto mode:
*Check if the banding is set to start regardless of the sensor detecting an object.
→ Turn OFF the power switch, and then turn it ON.
4) If the
START BUTTON LED
is blinking (manual) or banding is performed
automatically (auto) without any object:
*Check if the sensor is dirty.
→ Turn OFF the power switch, and then clean the object sensor.
5) If the band cannot be cut:
→ Ask for A/S as the cutter is expired.
6) If the deposition is weak:
*Check if the heater temperature is too low.
→ Increase the heater temperature by turning the heater temperature control knob
clockwise.
*Check if the band roll is set in the opposite direction.
→ Set it correctly according to “4. Band Installation”.
7) If the deposition is weak even though the temperature is raised using the
temperature control knob:
*Check the heater sheet.
→ Replace the heater sheet according to the replacement method.
*
Ask for A/S as the heater is expired.
8) If the deposited portion is scorched or odors (fumes) are generated at the
deposition:
→
Lower the temperature as the heater temperature is too high.
Summary of Contents for YL-420