7
Failed Band Removal
When the rail is jammed with the band:
1) Turn OFF the power switch.
2) Press the rail opening/closing lever
to open the rail.
3) Cut the band around the hold plate using scissors.
4) Turn the band roll counterclockwise to completely
remove the band.
5) Set the band according to “4. Band Installation”.
When the band is wound around the hold plate:
1) Turn OFF the power switch.
2) Cut the band that is wound around the hold plate,
as shown in the figure.
3) Pull the left end of the band to remove it.
4) Turn ON the power switch.
5) Press the feed button to feed the band
if the band is incorrectly set in the rail.
* The band is incorrectly set if the
FEED BUTTON LED
is blinking.
As such, take action as follows:
- If the band is fed well after pressing the feed button again:
Do the banding 2–3 times to ensure that the machine works
normally as the cut end of the band may become rough or wrinkled.
- If it does not work even after pressing the feed button again:
Open the front and band reel covers, cut the band (around the band set lever),
and remove it while pressing and holding the rail opening/closing lever.
When the power is ON, do not put your hand in the rail or hold plate.
Pay attention during auto mode because the machine may start operating
once a part of your body is detected.