KB 23 / KB 23-UL (E3.1) 02/2019
page 72/87
20.4 KB 23 / KB 23-UL (E3.1) technical data
Exterior dimensions
Width, net
mm /
inch
435 /
17.13
Height, gross (incl. feet)
mm /
inch
620 /
24.41
Depth, net
mm /
inch
520 /
20.47
Depth, gross (incl. door handle, I-panel, connection, and 30
mm for cable)
mm /
inch
600 /
23.62
Wall clearance (minimum)
mm /
inch
100 /
3.94
Wall clearance door open (minimum)
mm /
inch
100 /
3.94
Doors
Number of doors
1
Number of inner glass doors
1
Interior dimensions
Width
mm /
inch
222 /
8.74
Height
mm /
inch
330 /
12.99
Depth
mm /
inch
277 /
10.91
Interior volume
l /
cu.ft.
10 /
0.35
Steam space volume
l /
cu.ft.
Racks
Quantity of racks (regular)
2
Quantity of racks (max.)
3
Maximum load per rack
Kg /
lbs
12 /
26
Maximum permitted total load
Kg /
lbs
25 /
55
Weight
Weight (empty)
Kg /
lbs
44 /
97
Temperature data
Temperature range
°C
°F
0 to +100
4 to 212
Temperature fluctuation
at 5 °C
± K
0.2
at 40 °C
± K
0.2
Temperature uniformity (variation)
at 5 °C
± K
0.7
at 25 °C
± K
0.3
at 40 °C
± K
0.3
Heating up time
to 40 °C
min
11
Cooling down time from 40 °C
to 5 °C
min
61
Recovery time after doors
were open for 30 sec.
at 5 °C
min
5
at 40 °C
min
2
Electrical data
(model version KB023-230V)
IP system of protection acc. to EN 60529
20
Nominal voltage (±10 %) at 50 Hz power frequency
V
230
Current type
1N~
Power plug
Grounded plug
Nominal power
kW
0.34
Overvoltage category acc. to IEC 61010-1
II
Pollution degree acc. to IEC 61010-1
2
Chamber fuse 5x20 mm 230V, time-lag T, external
Amp
10
Summary of Contents for KB 23
Page 75: ...KB 23 KB 23 UL E3 1 02 2019 page 75 87 20 7 KB KB UL 23 dimensions...
Page 77: ...KB 23 KB 23 UL E3 1 02 2019 page 77 87...
Page 78: ...KB 23 KB 23 UL E3 1 02 2019 page 78 87...
Page 80: ...KB 23 KB 23 UL E3 1 02 2019 page 80 87...
Page 81: ...KB 23 KB 23 UL E3 1 02 2019 page 81 87 22 Product registration...