8.5.1 ELECTRIC PUMP
PROBLEM
PROBABLE CAUSE
SOLUTION
The lifting
platform during
the ascent and/or
descent vibrates
excessively or
Air present in the Hydraulic
circuit.
It is necessary to bleed the hydraulic circuit
by lifting and lowering the lifting platform a
few times.
The
lift
rises
slowly and with
difficulty
Oil too viscous
If the air temperature falls below -6°/-10° C,
the oil decreases its fluidity. To solve this
problem, lift and lower the lift a few times
so that the oil increases its temperature.
Operating on the
button panel, the
motor runs but
the lift does not
rise.
Oil level in the pump too low.
Remove the casing of the pump and check
the oil level through the plug (Figure 11). If
the level is too low, add ISO VG 10 hydraulic
oil.
Hydraulic pump problems
Contact the dealer or Bike-Lift - Europe s.r.l.
The motor does
not
run
when
operating on the
button panel
No voltage
Check the mains connection plug
Improper operation of the
button unit on the button
panel
Replace the button unit
The motor is short-circuited
Contact the dealer or Bike-Lift - Europe s.r.l.
Operating on the
button panel the
lifting
platform
does not descend
No voltage
Check the mains connection plug
Improper operation of the
button unit on the button
panel
Replace the button unit
Problems with the solenoid
valve which controls the
descent of the pump
Replace the solenoid valve (Figure 11)