Operating Manual no.
057-2-6-0016-R0
Version 2020
P. 21
EN
5.3
Commissioning
The tests to be carried out before using the machine have the task of verifying that the mechanical
and electrical installation (in the electro-hydraulic pump versions) has been carried out correctly
and there are no breakages or damages that could compromise the proper functioning and the
performance of the machine.
Make sure:
There are no signs of obvious breakage or damage of the mechanical structures;
The mechanical safeties previously described are functioning;
The connecting pipe between the pump and the hydraulic cylinder does not have any
cracks and is in good condition;
All the seegers placed on the pins are installed correctly
In the versions equipped with electro-hydraulic pump, also check that:
The electric cable and plug protections (not supplied, but to be installed by the User in
compliance with the Country's regulations) are in perfect condition;
The power plug is properly inserted in the socket;
The electrical power wiring between the pump and the socket is well positioned, not
twisted, does not interact with the passage routes or the storage spaces and does not
interfere with other machineries;
The connection to the electrical system is suitable for power and amperage in order to
power the electro-hydraulic pump (refer to the data on the plate shown on the lifting
platform).
The detail highlighted in blue indicates the casing that allows the
replacement of the oil plug specific for transport (to prevent spillage)
with that of normal operation provided with vent. We recommend
changing the plug when using the machine for the first time.