Page 10 of 69
Overfilling the LP Gas containers can result in uncontrolled gas flow, which can cause fire or
explosion. A properly filled container will contain approximately 80% of its volume as LP
Gas.
The following label has been placed in the recreational vehicle near the range.
IF YOU SMELL GAS
:
1. Extinguish any open flames, pilot lights and all smoking materials.
2. Do not touch electrical switches.
3. Shut off the gas supply at the container valve(s) or gas supply connection.
4. Open doors and other ventilating openings.
5. Leave the area until the odor clears.
6. Have the gas system checked and leakage source corrected before using again.
LP Gas regulators must always be installed with the diaphragm vent facing downward.
Regulators that are not in compartments have been equipped with a protective cover. Make
sure that the regulator vent faces downward and the cover is kept in place to minimize vent
blockage, which could result in excessive gas pressure causing fire or explosion.
FAILURE TO COMPLY COULD RESULT IN EXPLOSION RESULTING IN
DEATH OR SERIOUS INJURY!
QCC Type I Operating Instructions
1)
Make sure propane cylinder has propane.
2)
Be certain cylinder valve is closed.
3)
Hand tighten QCC Type I onto cylinder valve. Be sure appliance shut-off valves are in
the closed position.
4)
Slowly open cylinder valve. If valve is opened too quickly, the excess flow device will
be activated closing the flow of propane to the appliance. If the excess flow device is
activated, close appliance shut-off valves and wait 60 seconds to allow pressure in the
line to equalize. Additional equalization time may be needed depending on the length of
the hose.
5)
Turn on appliance by following manufacturer’s suggested lighting procedures.
6)
If appliance fails to light, close cylinder valve and appliance shut-off valves. Repeat
steps 1-5 being careful to open cylinder valve slowly.
Summary of Contents for T2801
Page 2: ...BIGFOOT TRAILER MANUAL DRAFT 8 APRIL 3 2008 ...
Page 36: ...Page 34 of 69 ...